Hardware information screens 217

Icon

Operational state

Meaning

Corrective action

(blue)

Initializing Device

is

initializing. Wait until initialization is complete.

(This icon should only be seen at

startup.)

(blue)

Profile pending

Device has a pending profile

assignment.

Turn server power off and apply the

new profile.

(yellow)

Degraded

Device is partially operational, but
capacity is lost.

Check and correct the Onboard
Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the
configuration.

BIOS level is not at a level that
supports Virtual Connect.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

Missing

Device is configured but not
accessible.

Insert the correct hardware module.

Failed

Device is not operational because

of an error.

Reset the device or application, or

replace the device.

Server Bay OA Communication Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Failed

Cannot communicate with the
device.

Do one or more of the following:

Reset the interconnect module.

Check if the physical device is
properly seated in the bay.

Check the IP address.