Installation 35

HP Virtual Connect Flex-10 Module guidelines

The following guidelines apply to the installation or replacement of HP Virtual Connect Flex-10 10Gb

Ethernet Modules:

Only install HP Virtual Connect Flex-10 Modules into bays horizontally adjacent to bays containing
HP Virtual Connect Flex-10 Modules.
If any other type of module is installed, the second one discovered is set to UNKNOWN and no
connections are made to the server NICs attached to the interconnect bay. The module is set to

UNKNOWN because it will be automatically removed from the VC domain when physically
removed from the interconnect bay.

Replacing a HP Virtual Connect Flex-10 Module with any other type of Virtual Connect Ethernet
module requires the module be administratively removed prior to replacement if the module is

connected to a Flex-10 NIC that corresponds to an Ethernet connection in a server profile. For

additional information, see "Administrative module removal (on page

210

)."

If the replacement module is not administratively removed, the module is marked as INCOMPATIBLE
and no connections are made to the server NICs attached to the interconnect bay.

An empty interconnect bay horizontally adjacent to a bay containing an HP Virtual Connect Flex-10
Module is treated as if it has a Flex-10 compatible Ethernet module for server configuration. If the

corresponding server NIC is Flex-10, it is partitioned according to the connections in the server
profile. Adding a module that does not support Flex-10 when the corresponding server is configured

for Flex-10 results in the module being set to INCOMPATIBLE.

Firmware requirements

IMPORTANT:

For optimal operation of HP Virtual Connect, use the recommended firmware

versions.

Always install the most current firmware for the following items:

Server blade system ROMs

Ethernet mezzanines

Fibre Channel mezzanines

HP BladeSystem Onboard Administrator

iLO

HP recommends using the HP BladeSystem c-Class Virtual Connect Support Utility to install HP Virtual

Connect module firmware. For the procedures, be sure to read the instructions on the web page and in

the HP BladeSystem c-Class Virtual Connect Support Utility release notes.
For additional information on required firmware versions and to download firmware upgrades, see the

HP website (

http://www.hp.com/go/bladesystemupdates

).

Virtual Connect and EBIPA

Enclosure Bay IP Addressing is used to specify IP addresses for the interconnect modules, which are then

provided to the modules by the Onboard Administrator.