Installing a vc-fc module – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 39

Advertising
background image

Installation 39

7.

Re-assign the server profiles or add the connections to the profiles, depending on what was done in

step 3.

Replacing a Virtual Connect Ethernet Module with an HP Virtual Connect Flex-10 Module in bays 1 or 2

1.

Upgrade the VC domain firmware to v2.00.

2.

Save the configuration.

3.

Upgrade any modules in bays 3 to 8 using the steps above.

4.

Save the configuration. This is very important.

5.

Remove the modules from bays 1 and 2.

6.

Install the HP Virtual Connect Flex-10 Modules in bays 1 and 2.

7.

Import the domain, and then select the option to restore the domain from a saved configuration file.

Possible errors
If the above steps are not followed exactly, the module might be set to the UNKNOWN or
INCOMPATIBLE state depending on how the error state was reached. The module should be physically

removed and administratively removed, if necessary. Then, the correct module type can be inserted.
If the above steps have been followed and the server is not connecting properly to the network, power

down the server, and then power it back up.

Installing a VC-FC module

1.

Remove the interconnect blank.

NOTE:

HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect

interconnect modules only.