Server management 105

With this 'forced' option selected, the server connection VLAN mappings are linked to the chosen shared
uplink set. Any change to the uplink VLAN mappings is reflected automatically on the server connection

using those shared uplink set VLAN mappings. Therefore, to minimize network outage time, any VLAN
mapping changes to the uplinks requires immediate changes being made to the VLAN tagging on the
servers.

No Forced VLAN Mappings
If the 'Force same VLAN mappings as Shared Uplink Sets' option is not selected, users can choose
available networks and assign a unique server VLAN associated with the network for this server port. Not
forcing VLAN mappings provides greater flexibility in selecting the set of networks to connect to each

server port, and enables administrators to specify server VLAN mappings independent of those assigned
by the network administrator for the shared uplink sets. The untagged option is always available, but it

might be unassigned, that is, any untagged frame from the server is dropped. Each network can be
selected only once per server port. Similarly, each server-assigned VLAN must be unique per server port.
This option is not available if the domain-wide 'Force server connections to use the same VLAN mappings

as shared uplink sets' checkbox on the Advanced Settings tab of the Ethernet Settings screen is selected.
If the selected network is part of a shared uplink set, it has an associated external VLAN mapping. This
external VLAN is used to pre-populate the server-assigned VLAN entry to maintain consistency throughout

the VC domain. However, multiple networks on different shared uplink sets can have the same external
VLAN mapping. If those networks are selected for the same server port, the user must edit the server

VLAN to ensure all VLANs are unique for each server port.
Server VLAN mappings are not linked to the uplink VLAN mappings. If a pre-populated server VLAN
mapping is accepted, and later the uplink VLAN mapping is changed, the changes are not propagated to