Reset virtual connect manager, Recovering remote enclosures – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 21

Advertising
background image

HP Virtual Connect Manager 21

Reset Virtual Connect Manager

Users must have Administrative privileges to reset the Virtual Connect Manager. In a multi-enclosure
environment, the Ethernet modules in bays 1 and 2 of the primary enclosure host the Virtual Connect

Manager.
To reset the Virtual Connect Manager application running on the primary Virtual Connect Ethernet
module, select Reset Virtual Connect Manager from the Tools pull-down menu. The Reset Virtual Connect

Manager screen is displayed.

If the Force Failover checkbox is selected and a Virtual Connect Ethernet module is available in the

alternate interconnect bay (interconnect Bays 1 and 2 can host the Virtual Connect Manager), the
GUI counts down from 90 seconds. Then the GUI is redirected to the alternate Virtual Connect
Ethernet module for logon after the Virtual Connect Manager has restarted.

If the Force Failover checkbox is not selected or a Virtual Connect Ethernet module is not available in
the alternate interconnect bay, the GUI counts down from 90 seconds, the Virtual Connect Manager

restarts on the current Virtual Connect Ethernet Module, and the user is presented the logon screen
for the current Virtual Connect Ethernet module after the Virtual Connect Manager has restarted.

When resetting the Virtual Connect Ethernet module, Virtual Connect Manager is temporarily unavailable
to the user. If failover is specified and a standby Virtual Connect Ethernet module is available, users are
logged off and must reconnect using the standby Virtual Connect Ethernet module IP address.

Recovering remote enclosures

If a previously saved configuration file is restored, the OA is reset to factory defaults, or the OA

associated with the remote enclosure is replaced, then the credentials of the remote enclosure must be
restored. If the IP link between the primary enclosure OA and the remote enclosure OA is lost, the remote

enclosure is also marked as NO-COMM. Ensure network connectivity before attempting credentials
recovery.