Ethernet settings (port monitoring) screen – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 64

Advertising
background image

Network management 64

Multifunction Gigabit server adapter. Only the primary MAC address is used by standard (not
multifunction) Ethernet devices.

If a server blade is moved from a Virtual Connect managed enclosure to a non-Virtual Connect
enclosure, the local MAC addresses on that server blade are automatically returned to the original

factory defaults.

If a server blade is removed from a bay within a Virtual Connect domain and installed in another

bay in the same Virtual Connect domain or in a bay in a different domain, it is assigned the new set
of addresses appropriate for that server location.

When Flex-10 technology is used, Virtual Connect will automatically reserve sixteen MAC addresses

for use by a dual-port Flex-10 LOM or mezzanine adapter. This may limit number of the server
profile that can be defined in a Virtual Connect domain.

When using the static, factory default MAC addresses, you cannot replace a server and have it appear to
the network as though the NIC hardware was not changed.

Ethernet Settings (Port Monitoring) screen

To access this screen, click Port Monitoring under Ethernet Settings in the left window, or on the home

page, click Port Monitoring in the Network section.
The port monitoring screen is accessible to all users with server and network administrator privileges. All

other users have read-only access.
Port monitoring enables a set of server ports to have their network traffic duplicated to an unused uplink
port for purposes of monitoring and/or debugging network traffic on those server ports.

CAUTION:

The network analyzer port should only be connected directly to a network

analyzer. Improper connection of this port or improper configuration of port monitoring could

result in network loops and cause a network outage.

Port monitoring is disabled in a mixed firmware environment. If any module in the domain is running a

version of firmware lower than VC v1.20a, port monitoring is automatically disabled.