Snmp – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 53

Advertising
background image

Command line 53

Item Description

VLanID (optional) The new VLAN ID to be used for the mapping server port to network. Valid values

include 1 to 4094.

Untagged

(optional)

Enables or disables the network to handle untagged packets. Only one network in

an Ethernet network connection is allowed to handle untagged packets. The default
value is "false". If a shared uplink set is being used, then untagged network is the

same as the native network if present, but any network can also be configured to

handle untagged packets.
When changing a network untagged option from true to false, the user is required to
provide a VLanID if the global option SharedServerVLanId is set to "false".

Examples

->set server-port-map MyProfile:1 Network1 VLanId=100
Modifies the VLAN ID of an existing server port network mapping

->set server-port-map MyProfile:1 Network1 Untagged=true
Modifies the existing server port network mapping to handle untagged packets

Item Description

show server-port-

map

Display a server port network mapping. This command cannot be used if the domain
setting, VLanTagControl, is set to "Tunnel".

Syntax

show server-port-map [<ConnectionID> | *]

Parameter

ConnectionID

The reference ID of an existing enet-connection associated with a profile and a

server port. The format of the ConnectionId is <ProfileName:PortNumber>.

Examples

->show server-port-map
Lists all the server port mappings

->show server-port-map MyProfile:1
Displays the server port mapping for a profile

->show server-port-map *
Displays detailed output of all the server port mappings

snmp

View and modify the SNMP configuration for VC-Enet and VC-FC modules, and add, modify, and remove

SNMP trap configurations related to trap destinations.
Supported actions: set, show

Item Description

set snmp

Modify the SNMP configuration for the VC Domain.

Syntax

set snmp <Type> [ReadCommunity=<ReadCommunityString>]
[SystemContact=<SystemContact>] [Enabled=<true|false>]
[SmisEnabled=<true|false>]

Parameter

Type (required)

Indicates for which I/O module the SNMP configuration should be applied
(required). Valid values include "Enet" and "FC".

Advertising