Command line 31

Item Description

Example

->show igmp
Displays IGMP Snooping settings

interconnect

Manage I/O interconnect modules.
Supported actions: help, remove, show

Item Description

remove interconnect

Remove a module from the domain that has been removed physically from an

enclosure. Normally this command is used if a module has been physically
removed from the enclosure. To be removed, the module must not be currently

in use by any element in the domain.

Syntax

remove interconnect <ModuleID|*>

Parameter

ModuleID(required)

The ID of the module to remove. The ID is in the format
<EnclosureID>:<BayNumber>. To display a list of the IDs corresponding

to modules in the domain, the show interconnect command can be used.

Examples

->remove interconnect enc0:2
Removes a specific interconnect module (bay 2) from the domain

->remove interconnect *
Removes all interconnect modules from the domain that are not present
physically in any enclosures

->remove interconnect enc0:*
Removes all interconnect modules that are not present physically in a specific

enclosure

Item Description

show interconnect

Display all interconnect modules known to the domain.

Syntax

show interconnect [ModuleID|*]

Property

ModuleID

ID of the interconnect module. “*” displays detailed view of all the modules in
the VC domain. If not specified, summary output of all the modules is displayed

Examples

->show interconnect
Displays a summary listing of all interconnect modules

->show interconnect *
Displays detailed information for all interconnect modules

->show interconnect *:5
Displays the detailed information for all enclosures with interconnect modules
in interconnect bay number 5