Without a recovery string – HP StorageWorks 2.128 SAN Director Switch User Manual

Page 69

Advertising
background image

Fabric OS 5.x administrator guide

69

The following options are available:

5.

Enter

2

.

If no password was previously set, the following message is displayed:

Recovery password is NOT set. Please set it now.

If a password was previously set, the following messages are displayed:

Send the following string to Customer Support for password recovery:

afHTpyLsDo1Pz0Pk5GzhIw==

Enter the supplied recovery password.

Recovery Password:

6.

Enter the recovery password (string).
The recovery string must be between 8 and 40 alphanumeric characters. HP recommends a random

string that is 15 characters or longer for higher security. The firmware prompts for this password only

once. It is not necessary to remember the recovery string because it is displayed the next time you

enter the command shell.
The

New password

prompt is displayed.

7.

Enter the boot PROM password, and then reenter it when prompted. The password must be eight

alphanumeric characters (any additional characters are not recorded). Record this password for

future use.
The new password is saved (the

saveEnv

command is not required).

8.

Connect to the active CP blade serially or by telnet and issue the

haEnable

command to restore HA,

and then fail over the active CP blade by issuing the

haFailover

command.

Traffic flow through the active CP blade resumes when the failover is complete.

9.

Connect the serial cable to the serial port on the new standby CP blade (previously the active

CP blade).

10.

Repeat

step 2

through

step 7

for the new standby CP blade (each CP blade has a separate boot

PROM password).

11.

Connect to the active CP blade serially or by telnet and issue the

haEnable

command to restore

high availability.

Without a recovery string

Although you can set the boot PROM password without also setting the recovery string, HP strongly

recommends that you set both the password and the string. If your site procedures dictate that you must

set the boot PROM password without the string, follow the procedure that applies to your switch model.

NOTE:

Setting the boot PROM password requires accessing the boot prompt, which stops traffic flow

through the switch until the switch is rebooted. Perform this procedure during planned down time.

Option

Description

1 Start system

Continues the system boot process.

2 Recovery password

Lets you set the recovery string and the boot PROM

password.

3 Enter command shell Provides access to boot parameters.