Specifications

N1528A and N1529A ACL Tape Drive Installation and User’s Guide544594-002

A- 2

Power Requirements

Power Requirements

The tape drives exhibits a nominal steady state AC power consumption of 192 watts,
and a maximum peak consumption of 240 watts.

Current

1.6 - 1.0 amperes (120 - 240 V ac)

Temperature, Humidity, and Altitude

Table A-2. Temperature, Humidity, and Altitude Specifications

Non-Operating - Long Term

Unpacked or Packed

Dry Bulb Temperature

-40°C to 60°C

Temperature Gradient

20°C/hour (across the range)

Temperature Shock

15°C (over 2 minutes)

Wet Bulb Temperature

30°C

Relative Humidity

5% to 95% (non-condensing)

Humidity Gradient

10%/hour.

Altitude (sea level)

-1000 feet to +10,000 feet

Transit - Short Term

Packed 7 days

Dry Bulb Temperature

-40°C to 60°C

Temperature Gradient

25°C/hour (across the range)

Temperature Shock

15°C (over 2 minutes)

Wet Bulb Temperature

30°C

Relative Humidity

5% to 95% (non-condensing)

Altitude (sea level)

-1000 feet to +10,000 feet