Syntax, Operands – HP XP7 Storage User Manual

Page 116

Advertising
background image

Operands of the group subcommand

Monitoring Data

PhyProc Long

Usage statistics about MPs and data recovery and reconstruction
processors

PhyCMPK Long

Usage statistics about access paths and write pending rate

If you run the Export Tool without specifying the long-range subcommand, the data stored in
the whole monitoring term will be exported.

The login subcommand must execute before the long-range subcommand executes.

Syntax

long-range

[[yyyyMMddhhmm][{+|-}ddhhmm]:[yyyyMMddhhmm][{+|-}ddhhmm]]

Operands

The value on the left of the colon (:) specifies the starting time of the period. The value on the right
of the colon specifies the ending time of the period. Specify the term within "Long Range From
XXX To XXX" which is output by the show subcommand.

If no value is specified on the left of the colon, the starting time for collecting monitoring data is
assumed. If no value is specified on the right of the colon, the ending time for collecting monitoring
data is assumed. The starting and ending times for collecting monitoring data are displayed in the
Monitoring Term area in the Monitor Performance window.

Figure 12 Starting and Ending Time for Collecting Monitoring Data

Description

Operand

yyyyMMdd

indicates the year, the month, and the day. hhmm indicates the hour and the

minute.

yyyyMMddhhmm

If yyyyMMddhhmm is omitted on the left of the colon, the starting time for collecting monitoring
data is assumed. If yyyyMMddhhmm is omitted on the right of the colon, the ending time for
collecting monitoring data is assumed.

Adds time (ddhhmm) to yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
201301120000+010130 indicates Jan. 13, 2013. 01:30.

+ddhhmm

Adds time to the starting time for collecting monitoring data, if yyyyMMddhhmm is omitted.

Subtracts time (ddhhmm) from yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,
201301120000-010130

indicates Jan. 10, 2013. 22:30.

-ddhhmm

Subtracts time from the ending time for collecting monitoring data, if yyyyMMddhhmm is
omitted.

Ensure that mm is 00, 15, 30, or 45. If you do not specify mm in this way, the value on the
left of the colon (:) will be rounded down to one of the four values. Also, the value on the
right of the colon will be rounded up to one of the four values. For example, if you specify
201301010013:201301010048

, the specified value is regarded as

201301010000:201301010100

.

116