Probable causes and recommended action

Export Tool messages

No host name is specified. Specify a host name.

Missing host name

No directory is specified for saving files. Specify the directory for saving
files.

Missing output directory

The Export Tool cannot find the user ID, which is used to log into SVP.
Specify the password.

Missing password

The svpip subcommand is not used. Use the svpip command.

Missing svpip

Specify the time range.

Missing time range

The Export Tool cannot find the user ID, which is used to log into SVP.
Specify the user ID.

Missing user ID

The value is outside the range.

Out of range: range

If the short-range subcommand or the long-range subcommand is used,
specify a value within the range from the monitoring start time to the
monitoring end time. For specification required when you narrow down the
file save period with a long-range subcommand, see

“long-range” (page 115)

.

If the set subcommand is used with the switch operand, specify a value
within the range of 1 to 15.

The user ID does not have the required permission.

Permission Denied.

The user ID needs to have at least one of permissions for Performance
Monitor, Continuous Access Synchronous, Continuous Access Synchronous
Z, Continuous Access Journal, and Continuous Access Journal Z.

An error occurs at the RMI server. For detailed information, see the HP XP7
Remote Web Console Messages
.

RMI server error (part-code, error-number)

The Export Tool cannot display the online help due to a system error.

Unable to display help message

The Export Tool cannot obtain the serial number due to a system error.

Unable to get serial number

SVP does not contain monitoring data.

Unable to get time range for monitoring

The Export Tool cannot read the command file. Specify the name of the
command file correctly.

Unable to read command file: file

The specified subcommand is unavailable.

Unable to use the command: command

The specified operand of the group subcommand is unavailable.

Unable to use the group name: operand

The Export Tool cannot resolve the host name. Specify the correct host name.

Unknown host: host

The Export Tool does not support the specified command. Specify a correct
command.

Unsupported command: command

The specified operand is not supported. Correct the specified operand.

Unsupported operand: operand

The specified option is not supported. Correct the specified option.

Unsupported option: option

Files exist in path.

Some file exists in path. What do you do?
clear(c)/update(u)/stop(p) You selected
"action". Is it OK? (y/n)

If you want to clear the files, press the <c> key.

If you want to overwrite the files, press the <u> key.

If you want to stop the operation, press the <p> key.

When you press a key, a message appears and asks whether to perform
the specified action.

To perform the specified action, press the <y> key.

To cancel the specified action, press the <n> key.

The retry subcommand is written in an incorrect position in the command
file.

Specify the following subcommand before
login subcommand: retry

Write the retry subcommand before the login subcommand.