Description

Operand

Examples

The examples below assume that the:

Starting time for collecting monitoring data is Jan. 1, 2013, 00:00,

Ending time for collecting monitoring data is Jan. 2, 2013, 00:00.

short-range 201301010930:201301011730

The Export Tool saves monitoring data within the range of Jan. 1, 9:30-17:30.

short-range 201301010930:

The Export Tool saves monitoring data within the range of Jan. 1, 9:30 to Jan. 2, 00:00.

shortrange:201301011730

The Export Tool saves monitoring data within the range of Jan. 1, 0:00-17:30.

short-range +0001:

The Export Tool saves monitoring data within the range of Jan. 1, 0:01 to Jan. 2, 00:00.

short-range -0001:

The Export Tool saves monitoring data within the range of Jan. 1, 23:59 to Jan. 2, 00:00.

shortrange:+0001

The Export Tool saves monitoring data within the range of Jan. 1, 0:00-00:01.

shortrange:-0001

The Export Tool saves monitoring data within the range of Jan. 1, 0:00-23:59.

short-range +0101:-0101

The Export Tool saves monitoring data within the range of Jan. 1, 1:01-22:59.

short-range 201301010900+0130:201301011700-0130

The Export Tool saves monitoring data within the range of Jan. 1, 10:30-15:30.

short-range 201301010900-0130:201301011700+0130

The Export Tool saves monitoring data within the range of Jan. 1, 7:30-18:30.

short-range 201301010900-0130:

The Export Tool saves monitoring data within the range of Jan. 1, 7:30 to Jan. 2, 00:00.

long-range

Description

The long-range subcommand is used to specify a monitoring term (time range) for collecting
monitoring data to be exported into files. Use this subcommand when you want to narrow the
export-target term within the stored data.

The long-range subcommand is valid for monitoring data in long range. The monitoring data
in long range is the contents displayed on the Physical tab of the Performance Management window
with selecting long-range as the storing period.

The monitoring items whose data can be stored in long range are limited. The following table
shows the monitoring items to which the long-range subcommand can be applied, and also
shows the operands to export those monitoring items.

Operands of the group subcommand

Monitoring Data

PhyPG Long

Usage statistics about parity groups

PhyLDEV Long

Usage statistics about volumes