HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 175

Advertising
background image

Configuring the Virtual Connect domain using the CLI 175

You can remove connections at any time (one at a time, from the bottom).

If the existing profile connections do not match the current FC/FCoE module configurations, the add

operation is not allowed.

The current maximum number of per server profile FC/FCoE connections mapped to the same I/O bay

is four, unless you are using the HP Integrity BL890c i4 Server Blade.

o

When FlexFabric modules exist in I/O bays 1 and 2, there can be an additional eight FCoE
connections that will get mapped to LOMs 3 and 4 on the blades in an Integrity BL890c i4 server.
The BL890c i4 server has CNA LOMs, which enable two FCoE connections to I/O bay 1 (from

LOMs 1 and 3) and two FCoE connections to I/O bay 2 (from LOMs 2 and 4).

The following table lists several scenarios that describe how adding FC/FCoE connections affects an existing
profile. The scenarios are true for FC module configurations and FC modules, as well as FCoE module

configurations and FCoE-capable modules.

Scenario Description

Existing profile
connections

Current FC module
configurations

Adding profile connections

1

Start with modules in Bays 3
and 4, create a profile, then

edit the profile and add
connections.

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Add connection, 2 times

2

Start with modules in Bays
3–6, create a profile, then

edit the profile and add
connections.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Add connection, 4 times

3

Start with modules in Bays 3
and 4, create a profile,
install modules into Bays 5

and 6, then edit the profile
and add connections.

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4
Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Add connection, 2 times

4

Start with modules in Bays 3
and 4, create a profile (add
2 connections), install

modules into Bays 5 and 6,
then edit the profile.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Bay 3 Bay 4
Bay 5 Bay 6

Add connection is disallowed
because the current FC module
configurations do not match

the existing connections in the
profile.
This profile is not useful after

the hot-plug install. To resolve
this issue, delete connections 3
and 4, save the profile, and

then scenario 3 applies.

Advertising