Command line 134

Management element help—provides a listing of objects that are supported with a specific

subcommand and a brief description of the management element and what it represents in the
management model:
->help devicebay

General Enclosure Device Bay settings and information

Supported Subcommands:
help
show

-----------------------------------------------------------------------

->show devicebay -help

Description:

This command displays all device bays in the domain

Syntax:

show devicebay [<DeviceBayName> | *]

Parameters:

DeviceBayName : The reference name of a device bay in the domain.
The format of the device bay name is

<EnclosureID:DeviceBay>


Examples:

- Display a summary listing of all device bays:
->show devicebay

- Show detailed information for all device bays:
->show device bay *

- Show detailed information for a specific device bay 2 of
a specific enclosure:
->show devicebay enc0:2

Output format

The CLI provides two different output formats:

Interactive user output format

Scriptable output format