Command line 99

Supported actions: help, show

Item

Description

show server-port

Display physical server port information. If the port is unlinked and no connectivity
exists, the cause is displayed. For more information about possible causes, see

"Port status conditions (on page

178

)."

Syntax

show server-port [<PortID>]

Parameter

PortID (Optional)

The reference of a port mapping ID. The PortID format is
<EnclosureID:IOBay:Port>. The PortID can be referenced from the ID column

in the summary. The detailed display shows all FlexNICs that could be associated

with a server port.

Examples

->show server-port

Displays a summary of all physical server ports

->show server-port *

Displays detailed information for all physical server ports

->show server-port enc0:3:d2

Displays detailed information for a specific server port

->show server-port enc0:1:d4

Displays detailed information for the Device Control Channel

server-port-map

Manage shared server downlink port mapping configuration.
Supported actions: add, help, remove, set, show

Item

Description

add server-port-map Add a new server port network mapping, and allow server ports to be shared

among multiple VC Ethernet networks.

Syntax

add server-port-map <ConnectionId> <Network Name>

[Uplinkset=<Uplink Set Name>] [VLanID=<VLan ID>]

[Untagged=<true|false>]

Parameters

ConnectionID

(required)

The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is <ProfileName:PortNumber>.

Network (required) The name of a valid network to which the mapping is added. A network can be

configured once for every profile connection. Every profile connection can be
configured for a maximum of 28 networks in legacy VLAN mode or 162 networks
in expanded VLAN mode.

Properties

Uplinkset (optional) The name of the shared uplink set to use with the server port mapping. If the domain

setting SharedServerVLanId is set to "true", Uplinkset is a required value.

VLanID (optional)

The VLAN ID to use for the mapping. Valid values include 1 to 4094. If the uplink
set name is specified, the VLanID property should not be specified, because the

server VLAN ID is forced to be same as the VLAN ID used when adding the network
to the shared uplink set.

Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in

an Ethernet network connection can handle untagged packets. The default value is
"false". If a shared uplink set is used, the untagged network is the same as the native
network, if present, but any other network can be configured to handle untagged

Advertising