HP StorageWorks XP Remote Web Console Software User Manual

Page 36

Advertising
background image

Table 2 Host Mode Options (continued)

When to select this option

Host mode options

No.

When all the following conditions are satisfied:

Automatic recognition
function of LUN

7

The host mode 00 Standard or 09 Solaris is used

SUN StorEdge SAN Foundation Software Version 4.2 or better is used

You want to automate recognition of increase and decrease of devices when
genuine SUN HBA is connected

When all the following conditions are satisfied:

No display for ghost
LUN

12

The host mode 08 HP is used

You want to suppress creation of device files for devices to which paths are
not defined.

When you want to be informed by SIM (service information message) that the
number of link failures detected between ports exceeds the threshold

SIM report at link failure

13

1

When all the following conditions are satisfied:

HP TruCluster with XP
Continuous Access
function

14

The host mode 07 Tru64 is used

You want to use TruCluster to set a cluster to each of P-VOL and S-VOL for
XP Continuous Access or HP XP Continuous Access Journal Software.

When all the following conditions are satisfied:

HACMP

15

The host mode 0F AIX is used

HACMP 5.1 Version 5.1.0.4 or later, HACMP4.5 Version 4.5.0.13 or later,
or HACMP5.2 or later is used

When Veritas Cluster Server is used.

Veritas Cluster Server

22

When you want to shorten the recovery time on the host side if the data transfer
failed.

REC Command Support

23

1

When all the following conditions are satisfied:

Set/Report Device
Identifier enable

33

The host mode 03 HP or 05 OpenVMS

2

is used.

You want to enable commands to assign a nickname of the device.

You want to set UUID to identify a logical volume from the host

When all the following conditions are satisfied:

UUID Option

34

The host mode 05 OpenVMS or 07 Tru64 is used

You want to set UUID to identify a logical volume from the host.

In case that you want to control the following ranges per host group when
receiving Target Reset:

Change the nexus
specified in the SCSI
Target Reset

39

Range of job resettings

Range of UAs (Unit Attentions) defined

When all the following conditions are satisfied:

V-Vol expansion

40

The host mode 0C Windows or 2C Windows Extension is used

You want to automate recognition of the TP-VOL capacity after increasing
the TP-VOL capacity

When you want to execute commands to recognize the device preferentially.

Prioritized device
recognition command

41

When IBM Z10 Linux is used.

Prevent OHUB PCI retry

42

To make the storage system return a “queue full” response to the host when the
command queue is full.

Queue Full response

43

36

Performing LUN Manager Operations

Advertising