Startup and check jet health – HP Scitex FB950 Printer series User Manual

Page 123

Advertising
background image

No

HP Scitex FB950 Printer

Image Quality Flowchart

1. STARTUP AND CHECK JET HEALTH

© Hewlett-Packard Development Company, L.P.

START

LOAD

MEDIA

• Clean media, check for damage.
• Configure media (User Guide, Chapter 2).
• Load media (User Guide, Chapter 2).

CHECK

JET HEALTH

Run AutoJet.

(Menu > Calibrate > Auto Calibrations > AutoJet Calibration)

(User Guide, Chapter 4)

Repeat Print Prime Bars and check quality again.

If OK,

go to next page.

If not OK,

check calibrations and troubleshooting. Repeat

Print Jet Out Lines and check quality again.

(Calibrations: User Guide, Chapter 4)

(Troubleshooting: page 110)

Is today’s Prime Bars print

comparable to

yesterday’s best

Prime Bars print?

Yes

3. Print Prime Bars, compare to previous day’s print.

Verify jet replacement with Jet Out Lines.

If all jets working or replaced, go to next page; else run

AutoJet (see below).

(Menu > Tools > Maintenance > Print Jet Out Lines)

(User Guide, Chapter 4)

DAILY

STARTUP

TO

PAGE 2

1. Print Prime Bars

2. Purge and Wipe the heads

Advertising