Replace the UV lamp filters (quarterly)

Lamp filters keep ink dust and other debris from entering the air-cooled lamp area. If the filters become
clogged, the lamps may over heat, reducing the life of the bulbs. Over heating causes printing to stop,
which can ruin a print job.

1.

Remove the original air filters for both carriage lamps (B in photo below).

2.

Install the new air filters by insert the corner tabs (A in photo in previous step) under the corner
slots (C in photo in previous step) on top of the lamps.