About changing tiering policy groups, Changing a tiering policy – HP XP P9500 Storage User Manual

Page 71

Advertising
background image

2.

Execute the

KTQSTATS

command.

The volume I/O performance information is acquired.

Reference scripts

For details about how to create the script, see sample script KTDEMO14.

Example:

The following shows an example of the volume I/O performance information for tiering policy group
TPG1 acquired by executing sample script KTDEMO14 (

KTLOAD

and

KTQSTATS

commands).

Tiering Policy Group Name : TPG1

Monitor Interval Time(sec): 600

Volume I/O statistics

-------------------------------------------------------

11:23:00 - 11:33:00

-------------------------------------------------------

DEVN,Volser,STORGRP,SN ,CU,CCA,Tier1 IOPS,Tier2 IOPS,Tier3 IOPS

1101,VOL001,SG1 ,14001,00, 01, 100, 253, 1486

1201,VOL002,SG1 ,14001,00, 01, 20, 0, 0

-------------------------------------------------------

11:33:00 - 11:43:00

-------------------------------------------------------

DEVN,Volser,STORGRP,SN ,CU,CCA,Tier1 IOPS,Tier2 IOPS,Tier3 IOPS

1101,VOL001,SG1 ,14001,00, 01, 60, 0, 0

1201,VOL002,SG1 ,14001,00, 01, 4, 0, 0

:

Related topics

Creating a tiering policy group definition file

, page 65

KTLOAD

, page 94

KTQSTATS

, page 102

KTDEMO14 (Check I/O performance information)

, page 200

About changing tiering policy groups

This section describes how to make changes to tiering policy groups.

Changing a tiering policy

If you need to change a tiering policy due to lowered I/O performance or a change in the purpose
for which volumes are being used, modify the created tiering policy information CSV file, update the
definition, and then apply the update to the storage system.

1.

Change the tiering policy information CSV file.

2.

Execute the

KTIMPORT

command.

The tiering policy group definition file is updated with the contents of the modified tiering policy
information CSV file.