Pr s – HP Surestore 64 Director Switch User Manual
Page 204

188
Appendix
P
R
S
Non-redundant director must be
offline to install firmware.
If the director has only a single CTP card, it must be offline to
initiate a firmware installation. Take director offline and try again.
Message
Cause/Solution
Performing this operation will
change the current state to
Offline.
This operation causes the director to go offline. N/A. An
informational message.
Performing this operation will
change the current state to
Online.
This operation causes the director to go online. N/A. An
informational message.
Product Manager error
<number>.
The director Product Manager encountered an internal error and
cannot continue. Report the problem to support personnel.
Product Manager error
<number>
A Product Manager window is currently open. Informational
message only.
Message
Cause/Solution
R_A_TOV must be greater than
E_D_TOV.
R_A_TOV must be greater than E_D_TOV. Change one of the
values so that R_A_TOV is greater than E_D_TOV.
Message
Cause/Solution
Send firmware operation failed.
Send firmware has failed. Retry the operation. If the condition
persists, contact support personnel.
Message