HP Surestore 64 Director Switch User Manual

Page 87

Advertising
background image

Hardware View

71

Mo

ni

to

ri

n

g

a

n

d

Ma
na
g

ing
t

h

e D

ir

e

ct

o

r

connected to another director or a switch. This field displays “NA” if a segmented
E_Port or invalid attachment operating state has not occurred.

Refer to the section on joining zoned fabrics in the hp surestore director fc-64
Planning Guide
(A6534-90903).

Reason messages for segmentation can include:

– Incompatible operating parameters. Operating parameters, such as resource

allocation time-out values (R_A_TOV) or error-detect time-out values (E_D_TOV),
are inconsistent. Refer to Configure Operating Parameters on page 110 for more
information.

– Duplicate domain IDs. Identical preferred domain IDs are configured for two or

more directors or switches. Refer to Configure Operating Parameters on page 110
for more information.

– Incompatible zoning configurations. Refer to the hp surestore director fc-64

Planning Guide (HP A6534-90903) and the hp surestore director fc-64 Installation
and Service Manual
(HP A6534-90902) for more information on zoning.

– Build fabric protocol error.

– No principal switch. A principle switch is not defined for the fabric.

– No response from the attached switch.

Reason messages for an invalid attachment can include:

– 01 Unknown. The reason is not known.

– 02 ISL connection not allowed on this port. ISL is connected to a port configured as

an F_Port.

– 03 ELP rejected by the attached switch. This director or switch transmitted an

exchange link protocol (ELP) frame that was rejected by the switch at the other end
of the ISL.

– 04 Incompatible switch at other end of the ISL. The switch is configured for Open

Fabric mode, and the switch at the other end of the ISL is a McDATA switch
configured for McDATA Fabric mode.