Features – HP NetStorage 6000 User Manual

Page 156

Advertising
background image

System Specifications
Features

C-5

Features

Feature

Description

Self-restart
Capability

Automatic Server Restart (ASR) that reboots incase
of embedded NOS hang

Environmental
Monitoring

Temperature, voltage, and fan-speed monitoring with
alarm capability

Self-Correcting
Memory

ECC capable with hardware error scrubbing; corrects
single bit errors, detects multiple bit errors

Hot-Swap
Subsystem

•

Supports 36GB and future low profile and half height
SCSI hard disks

•

Up to 10 hard disks

RAID Disk Array
Controller

•

Hardware RAID accelerator with 32MB of NVRAM

•

RAID5

•

Supports up to 10 hard disks with hot swap

•

Maximum RAID5 group of 8 drives

•

32MB NVRAM for cached write protection

•

Support for SMART capable disk drives

•

Automatic detection of hard disk failure with
automatic rebuild to global hot spare

Power Supply
Modules

•

Triple, redundant with hot swap

•

System can tolerate failure of one supply (two
required for minimum operation) (2+1 operation)

•

Audible alarm and network alarm for failure

Fans

•

2 Redundant fan assemblies with fan-speed
monitoring for system cooling

•

Fan hot swap supported

Boot Time

Seconds from power on to file system available (after
proper shutdown, one 5 drive RAID5 partition, typical)

UPS Support

•

External Uninterruptible Power Supply (UPS)
monitoring through integrated serial port (DB9 male)

•

System shutdown initiated battery critical error
reported by UPS

•

Requires Sine-wave output

•

Support for the following APC Brand UPS:

•

APC Smart-UPS 700 Model APC SU700RMNET

Advertising