Configuring Your System and Network

Alert Settings

3-8

SNMP/Network Management Settings

If you are using a Simple Network Management Protocol (SNMP) tool,
you can define the names of the servers to receive notification in case of a
failure.

To define the servers to receive notification:

1

Using the NetStorage web interface, click the Configuration tab, then
select Alert Settings > SNMP/Network Management.
By default, the Community String field is set to

public

and the Trap

Destination fields are blank.

2

In the Trap Destination fields, enter the IP addresses or names of the
servers you want the system to notify (up to five).

3

Enter a value in the Volume Capacity Threshold field to receive a
warning message if your volume gets to a certain capacity. By default,
the field is set to 95 percent

4

Click either:

•

Send SNMP Test Trap to send a cold boot test trap to the destination
addresses and save your changes.

•

Apply to only save your settings.

Note

The information on this screen is optional. Blank fields do not affect the
functionality of the device.