Viewing virtual disks, Viewing hbas – HP OneView for VMware vCenter User Manual

Page 71

Advertising
background image

•

Array Disk Emulation Type (HP XP P9000 and HP XP arrays only)—LDEV emulation type.

•

Replicated—Specifies whether the disk is replicated

•

Physical Device Type—The type of device in the CPG (applies only to HP 3PAR StoreServ).
The types can be FC, NL, or SSD.

•

Zero Detection—Detect and discard zeros during volume copying (applies only to HP 3PAR
StoreServ)

•

Volume ID—Internal volume ID (applies only to HP 3PAR StoreServ)

•

Volume Status—Volume health status (applies only to HP 3PAR StoreServ)

•

Drive Speed—Physical drive speed (applies only to HP 3PAR StoreServ)

•

Creation Time—Source volume creation time (applies only to HP 3PAR StoreServ)

•

Expiration Time—Source volume expiration time (applies only to HP 3PAR StoreServ)

•

Retention Time—Source volume retention time (applies only to HP 3PAR StoreServ)

•

User Space Warning—Alert threshold for a volume's User CPG (applies only to HP 3PAR
StoreServ)

•

User Space Limit—Write failure threshold for a volume's User CPG (applies only to HP 3PAR
StoreServ)

•

Copy Space Warning—Alert threshold for a volume's Copy CPG (applies only to HP 3PAR
StoreServ)

•

Copy Space Limit—Write failure threshold for a volume's Copy CPG (applies only to HP 3PAR
StoreServ)

Viewing virtual disks

The virtual disks page displays the following information:

•

Virtual Disk Name—Virtual disk name assigned by VMware

•

Virtual Disk Type—Virtual disk type (VMDK or RDM)

•

Virtual Machine—Name of the VM associated with the selected VMDK or RDM

•

Datastore—Datastore name or the .vmdk name for the RDM

•

Provisioned Capacity—Disk capacity visible to a VM using this VMDK or RDM

•

Allocated Capacity—Disk capacity reserved by VMware for the VMDK or RDM

For an RDM, this value will match the provisioned capacity value. For a VMDK, this value
might be less than the provisioned capacity value if VMware thin provisioning is used. This
is separate from thin provisioning configured in the storage array.

•

VMware Provisioned—Thick or thin

Viewing HBAs

The HBAs page displays the following information:

•

Host Names—Host name or cluster host names

•

Type—HBA type

•

VMware Device Identifier—HBA identifier assigned by VMware

•

WWN/IQN—HBA WWN

NOTE:

HBA WWN address is not available for HP MSA SAS arrays.

•

Label—HBA identifier assigned by VMware

Using the Storage Module for vCenter

71

Advertising