62 new threshold alerts dialog box–second screen – HP StorageWorks 2.140 Director Switch User Manual

Page 142

Advertising
background image

Configuring the director

142

4.

Click one of the following on the list under the Name field:
• Rx Throughput—An alert will occur if the threshold set for receive throughput is reached
• Tx Throughput—An alert will occur if the threshold set for transmit throughput is reached.
• Rx or Tx Throughput—An alert will occur if the threshold set for either receive or transmit

throughput is reached.

5.

Click Next.

A new screen is displayed with additional parameters, as shown in

Figure 62

. The name

configured for the alert is displayed at the top of the screen.

NOTE:

Click Previous if you need to return to the previous screen.

Figure 62

New Threshold Alerts dialog box–second screen

6.

Enter a percentage from 1 through 100 for % utilization.

When throughput reaches this percentage of port capacity, a threshold alert will occur.

7.

Enter the amount of cumulative minutes in which the % utilization should persist during the

notification interval before an alert is generated.

You can also click At any time if you want an alert to occur whenever the set % utilization is

reached. The valid range is from 1 to the interval value set in

step 8

.

8.

Enter the interval in minutes in which throughput is measured and threshold notifications can

occur.

The valid range is 5 minutes to 70,560 minutes (7 weeks).