Installation range hood, Instructions, Before you begin – GE JV347HWW User Manual

Page 6: Important, Warning

Advertising
background image

BEFORE YOU BEGIN

Installation

Range Hood

Instructions

Read these instructions completely and carefully.

‡

IMPORTANT –

Save these instructions for

local inspector’s use.

‡

IMPORTANT –

Observe all governing

codes and ordinances.

‡

Note to Installer –

Be sure to leave these

instructions with the Consumer.

‡

Note to Consumer –

Keep these instructions

for future reference.

‡ 6NLOOOHYHO² Installation of this appliance requires

basic mechanical and electrical skills.

‡ &RPSOHWLRQWLPH² 30 minutes–3 hours
‡ Proper installation is the responsibility of the installer.
‡ Product failure due to improper installation is not

covered under the Warranty.

NOTE: 5HDGWKHGXFWZRUNVHFWLRQVRQO\LI\RXGRQRW
KDYHH[LVWLQJGXFWZRUN,I\RXKDYHH[LVWLQJGXFWZRUN
VNLSWRWKH´'DPDJHµVHFWLRQDQGSURFHHG

WARNING –

725('8&(7+(5,6.2)),5($1'

723523(5/<(;+$867$,5%(685(72'8&7$,52876,'(³
'21279(17(;+$867$,5,17263$&(6:,7+,1:$//625
&(,/,1*625,172$77,&6&5$:/63$&(625*$5$*(6
The venting system must exhaust to the outside.
This hood can be vented vertically through upper cabinets or

horizontally through an outside wall. Ductwork is not included.

([KDXVWFRQQHFWLRQ

The hood exhaust has been designed to mate with

standard 3

1

ø

4

s x 10s rectangular ducting or 7s diameter

round ducting.
If a 6s round duct is required, a rectangular-to-round

transition adaptor must be used*. Do not use less than a

6s diameter duct.

0D[LPXPGXFWOHQJWK

For satisfactory air movement, the total duct length

of a 3

1

ø

4

s x 10s rectangular, 6s or 7s diameter round

duct VKRXOGQRWH[FHHGHTXLYDOHQWIHHW6HH

WKH:25.6+((7²&$/&8/$7(727$/(48,9$/(17

'8&7:25./(1*7+VHFWLRQ
NOTE:
It is important that ducting be installed using the

most direct route and with as few elbows as possible.

This ensures clear venting of exhaust and helps prevent

blockages. Also, make sure dampers swing freely and

nothing is blocking the ducts. When applicable, install any

makeup (replacement) air system in accordance with local

building code requirements. Visit GEAppliances.com for

available makeup air solutions.

(OERZVWUDQVLWLRQVZDOODQGURRIFDSVHWF

present additional resistance to airflow and are equivalent

to a section of straight duct longer than their actual

physical size. When calculating the total duct length, add

the equivalent lengths of all transitions and adaptors plus

the length of all straight duct sections. The charts on the

following pages show you how to calculate total equivalent

ductwork length using the approximate feet of equivalent

length of some typical ducts.

'8&7:25.5(48,5(0(176

WARNING –

Before beginning the

installation, switch power off at service panel and

lock the service disconnecting means to prevent power

from being switched on accidentally. When the service

disconnecting means cannot be locked, securely fasten

a prominent warning device, such as a tag, to the

service panel.

)25<2856$)(7<

Questions? Call 800.GE.CARES (800.432.2737)

RUYLVLWRXU:HEVLWHDW

GEAppliances.com

An optional Power Cord Connection Kit, model JXHC1,

is available at extra cost from your GE supplier for

installation using a standard 3-prong, grounded wall

outlet. Follow the Installation Instructions packed with

the kit to connect the power cord to the range hood.

OPTIONAL POWER CORD KIT JXHC1

6

*

IMPORTANT: If a rectangular-to-round

transition adaptor is used, the bottom

corners of the damper will have to be

cut to fit, using the tin snips, in order

to allow free movement of the damper.

Equivalent lengths of duct pieces

are based on actual tests and reflect

requirements for good venting

performance with any hood.