Installation instructions – GE JV347HWW User Manual

Page 7

Advertising
background image

7

DUCT

(48,9$/(17 180%(5



3,(&(6

/(1*7+

[ 86('

727$/

3

1

ø

4

s

x 10s 1 Ft.

x ( )

=

Ft.

Rect.,

straight

7s Round, 1 Ft.

x ( )

=

Ft.

straight

6s Round, 1 Ft.

x ( )

=

Ft.

straight

3

1

ø

4

s

x 10s

14 Ft.

x ( )

=

Ft.

Rect.

90°

elbow

3

1

ø

4

s

x 10s

8 Ft.

x ( )

=

Ft.

Rect.

45°

elbow

3

1

ø

4

s

x 10s

33 Ft.

x ( )

=

Ft.

Rect.

90°

flat

elbow

3

1

ø

4

s

x 10s

24 Ft.

x ( )

=

Ft.

Rect.

(18 ft. w/o

wall

cap

damper)

x ( )

=

Ft.

with

damper

3

1

ø

4

s

x 10s

2 Ft.

x ( )

=

Ft.

Rect.

to

6s round

transition

3

1

ø

4

s

x 10s

4 Ft.

x ( )

=

Ft.

Rect.

to

6s round

transition

90°

elbow

6s Round, 25 Ft.

x ( )

=

Ft.

90°

elbow

6s Round, 16 Ft.

x ( )

=

Ft.

45°

elbow

Subtotal column 1

=

Ft.

:25.6+((7³&$/&8/$7(727$/(48,9$/(17'8&7:25./(1*7+

DUCT

(48,9$/(17  180%(5 

3,(&(6

/(1*7+

; 86('

 727$/

6s

Round 53 Ft.

x ( )

=

Ft.

wall

cap

(39 ft. w/o

with

damper)

x ( )

=

Ft.

damper

6s

Round 72 Ft.

x ( )

=

Ft.

roof

cap

6s Round 3 Ft.

x ( )

=

Ft.

to

3

1

ø

4

s

x 10s

rect.

transition

6s Round 9 Ft.

x ( )

=

Ft.

to

3

1

ø

4

s

x 10s

rect.

transition

90°

elbow

7s Round, 14 Ft.

x ( )

=

Ft.

90°

elbow

7s Round, 9 Ft.

x ( )

=

Ft.

45°

elbow

7s

Round 28 Ft.

x ( )

=

Ft.

wall

cap

(21 ft. w/o

with

damper)

x ( )

=

Ft.

damper

7s

Round 39 Ft.

x ( )

=

Ft.

roof

cap

7s Round 1 Ft.

x ( )

=

Ft.

to

3

1

ø

4

s

x 10s

rect.

transition

7s

Round

5 Ft.

x ( )

=

Ft.

to

3

1

ø

4

s

x 10s

rect.

transition,

90°

elbow

Subtotal column 2 =

Ft.

Subtotal column 1 =

Ft.

Total ductwork

=

Ft.

Installation Instructions

MAXIMUM DUCT LENGTH: For satisfactory air movement,

the total duct length of a 3

1

ø

4

s x 10s rectangular, 7s diameter

round duct VKRXOGQRWH[FHHGHTXLYDOHQWIHHW
NOTE:
Any home ventilation system, such as a ventilation

hood, may interrupt the proper flow of combustion air and

exhaust required by fireplaces, gas furnaces, gas water

heaters and other naturally vented systems. To minimize the

chance of interruption of such naturally vented systems, follow

the heating equipment manufacturer’s guidelines and safety

standards such as those published by NFPA and ASHRAE.

When applicable, install any makeup (replacement) air system

in accordance with local building code requirements. Visit

GEAppliances.com for available makeup air solutions.

Advertising