GE P2B940DEFWW User Manual

Page 2

Advertising
background image

CONNECTOR HOOKUP

Pressure

regulator

Gas Flow into Range

Gas Flow into Range

Flex

connector

(6 ft. max.)

Adapter

Installer: Inform the consumer of the location of the gas shut-off valve.

1/2” or 3/4”

Gas pipe

Adapter

Gas

shut-off

valve

Pressure

regulator

Elbow

Elbow

Nipple

Union

Nipple

Gas

shut-off

valve

1/2” or 3/4”

Gas pipe

Flexible

Option

Rigid Pipe

Option

6

GAS SUPPLY

WARNING

Fire Hazard: Do not use a

flame to check for gas leaks.

WARNING

Explosion Hazard: Do not

exceed 25 ft-lbs of torque when making gas
line connections. Overtightening may crack
the pressure regulator resulting in fire or
explosion hazard.
Gas Pressure Regulator

You must use the gas pressure regulator supplied

with this range. For proper operations the inlet

pressure to the regulator should be as follows:

Natural Gas:

Minimum pressure: 6” of Water Column

Maximum pressure: 13” of Water Column

LP Gas:

Minimum pressure: 11” of Water Column

Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure

contact local gas supplier.
Shut off the main gas supply valve before

disconnecting the old range and leave it off

until the new hook-up has been completed.

Don’t forget to relight the pilot on other gas

appliances when you turn the gas back on.
Because hard piping restricts movement of

the range, the use of a CSA International-

certified flexible metal appliance connector is

recommended unless local codes require a hard-

piped connection.
If the hard piping method is used, you must

carefully align the pipe; the range cannot be

moved after the connection is made.

To prevent gas leaks, put pipe joint compound on,

or wrap pipe thread tape with Teflon* around, all

male (external) pipe threads.
A. Install a manual shut-off valve in the gas line

in an easily accessed location outside of the

range. Make sure everyone operating the

range knows where and how to shut off the

gas supply to the range.

B. Install male 1/2” flare union adapter to the 1/2”

NPT internal thread at inlet of regulator. Use a

backup wrench on the regulator fitting to avoid

damage.

C. Install male 1/2” or 3/4” flare union adapter to

the NPT internal thread of the manual shut-off

valve, taking care to back-up the shut-off valve

to keep it from turning.

D. Connect flexible metal appliance connector

to the adapter on the range. Position range to

permit connection at the shut-off valve.

E. When all connections have been made, make

sure all range controls are in the off position

and turn on the main gas supply valve.

Use a liquid leak detector at all joints and

connections to check for leaks in the system.

When using pressures greater than 1/2 psig

to pressure test the gas supply system of the

residence, disconnect the range and individual

shut-off valve from the gas supply piping. When

using pressures of 1/2 psig or less to pressure

test the gas supply system, simply isolate the

range from the gas supply system by closing the

individual shut-off valve.
When checking for proper operation of the

regulator, the inlet pressure must be at least 1”

greater than the operating (manifold) pressure as

given on rating label of product.

*Teflon: Registered trademark of DuPont

6

GAS SUPPLY (CONT)

8

CHECK SURFACE BURNERS

Push and turn knob to LITE position. You will hear

a clicking sound indicating proper operation of

the spark module. Once the air has been purged

from the supply lines, burners should light within

4 seconds. After burner lights, rotate knob out of

the LITE position. Try each burner in succession

until all burners have been checked.
Quality of Flames
The flame quality of the burners needs to be

determined visually.
If burner flames look like (A), call for service.

Normal burner flames should look like (B) or (C),

depending on the type of gas you use
With LP gas, some yellow tipping on outer cones

is normal.

WHEN ALL HOOKUPS ARE

COMPLETED

Make sure all controls are left in the off position.

Make sure the flow of combustion and ventilation

air to the range is unobstructed.

Check that all packing materials and tape have

been removed. This will include tape on metal

panel under control knobs (if applicable), adhesive

tape, wire ties, cardboard and protective plastic.

Failure to remove these materials could result in

damage to the appliance once the appliance has

been turned on and surfaces have heated.

& 6RIWEOXHIODPHV³
Normal for natural gas

(B) Yellow tips on
RXWHUFRQHV³
Normal for LP gas

$ <HOORZIODPHV³
Call for service

9

INSTALL AND CHECK

ANTI-TIP DEVICE

WARNING

Never completely remove the

leveling leg as the range will not be secured to
the anti-tip device properly.

Follow instructions supplied with ANTI-TIP bracket

Anti-Tip Bracket

Kit Included

11

FINAL INSTALLATION CHECKLIST

‡&KHFNWRPDNHVXUHWKHFLUFXLWEUHDNHULVFORVHG 5(6(7 RUWKHFLUFXLWIXVHVDUHUHSODFHG
‡%HVXUHSRZHUWRWKHEXLOGLQJLVLQVHUYLFH
‡&KHFNWKDWDOOSDFNLQJPDWHULDOVDQGWDSHKDYHEHHQUHPRYHG7KLVLQFOXGHVDOODGKHVLYHWDSHZLUH

ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the

appliance once the appliance has been turned on and surfaces have heated.

‡&KHFNWKDWWKHGRRUDQGGUDZHUDUHSDUDOOHOWRHDFKRWKHUDQGWKDWERWKRSHUDWHVPRRWKO\,IWKH\GRQRW

see the Owner’s Manual for adjustment instructions.

‡&KHFNWRPDNHVXUHWKDWWKHUHDUOHYHOLQJOHJLVIXOO\HQJDJHGLQWRWKH$QWL7LSEUDFNHWDQGWKDWWKH

bracket is securely installed.

OPERATION CHECKLIST

‡&KHFNWKDWWKHFORFNGLVSOD\LVHQHUJL]HG,I¶EDGOLQH·DSSHDUVLQWKHGLVSOD\GLVFRQQHFWSRZHU

immediately. Recheck the range wiring connections. If range wiring is correct, have building wiring

checked for proper connections and voltage.

‡Activate BROIL and make sure the element glows within 60 seconds. Cancel BROIL when glow is detected.

If glow is not detected within the time limit, recheck the range wiring

connections. If range wiring is correct, have building wiring checked for proper connections and voltage.

‡%HVXUHDOOUDQJHFRQWUROVDUHLQWKH2))SRVLWLRQEHIRUHOHDYLQJWKHUDQJH

1

ELECTRICAL REQUIREMENTS

WARNING:

This appliance must be

properly grounded.

WARNING:

All new constructions, mobile

homes, recreational vehicles and installations where
local codes do not allow grounding through neutral,
require a 4-conductor UL-listed range cord.

WARNING:

To prevent fire or shock, do

not use an extension cord with this appliance.

WARNING:

To prevent shock, remove

house fuse or open circuit breaker before
beginning installation.

We recommend you have the electrical wiring
and hookup of your range connected by a
qualified electrician. After installation, have the
electrician show you how to disconnect power
from the range.

You must use a single-phase, 120/208 VAC or
120/240 VAC, 60 hertz electrical system. If you
connect to aluminum wiring, properly installed
connectors approved for use with aluminum
wiring must be used.

Effective January 1, 1996, the National Electrical
Code requires that new construction (not
existing) utilize a 4-conductor connection to an
electric range. When installing an electric range
in new construction, mobile home, recreational
vehicle, or an area where local codes prohibit
grounding through the neutral conductor, refer to
the section on four-conductor branch circuit
connections.

Check with your local utilities for electrical codes
which apply in your area. Failure to wire your
oven according to governing codes could result

in a hazardous condition. If there are no local
codes, your oven must be wired and fused to
meet the National Electrical Code, NFPA No.
70 – latest edition, available from the National
Fire Protection Association.

This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded, 40 amp (minimum)
branch circuit protected by a circuit breaker
or time-delay fuse.
Use only a 3-conductor or a 4-conductor

UL-listed range cord. These cords may be

provided with ring terminals on wire and a strain

relief device.

A range cord rated at 40 amps with 125/250

minimum volt range is required. A 50 amp range

cord is not recommended but if used, it should

be marked for use with nominal 1

3

ø

8

” diameter

connection openings. Care should be taken to

center the cable and strain relief within the

knockout hole to keep the edge from damaging

the cable.

The rating plate is located on the oven frame or

on the side of the drawer frame.
Note: Use of automatic, wireless or wired external

switches that shut off power to the appliances,

are not recommended for this product.

2

POWER CORD AND CONDUIT INSTALLATION

A

Access the terminal block by removing

wire cover screws using a 1/4” nut driver.
Do not discard these screws.

B

For power cord and 1” conduit only, remove

the knockout ring (1

3

ø

8

”) located on bracket

directly below the terminal block. To

remove the knockout, use a pair of pliers

to bend the knockout ring away from the

bracket and twist until ring is removed.

C

For power cord installations only (see the

next step if using conduit), assemble the

strain relief in the hole. Insert the power

cord through the strain relief and tighten.

Allow enough slack to easily attach the

cord terminals to the terminal block. If

tabs are present at the end of the winged

strain relief, they can be removed for

better fit.

NOTE: Do not install the power cord

without a strain relief. The strain relief

bracket MUST be installed before

reinstalling the rear range wiring cover.

D

For 3/4” conduit installations only, purchase

a squeeze connector matching the diameter

of your conduit and assemble it in the hole.

Insert the conduit through the squeeze

connector and tighten. Allow enough slack

to easily attach the wires to the terminal

block. NOTE: Do not install the conduit

without a squeeze connector. The

squeeze connector MUST be installed

before reinstalling the rear range wiring

cover.

PROCEED TO STEP 3 or 4

Wire cover

Wire cover

5 screws to

remove wire

cover

5 screws to

remove wire

cover

Retaining

tabs

Retaining

tabs

Knockout

ring in

bracket

Knockout ring

removed

Terminal block

(appearance

may vary)

3

3-WIRE INSTALLATION (GROUND IS THROUGH THE NEUTRAL WIRE)

WARNING:

Shock Hazard

The neutral wire and ground strap must be

connected as shown below for the range to be

properly grounded. Do not remove the ground

strap. Failure follow this instruction may result

in potential shock hazard.

WARNING:

Fire hazard

Terminal block screws must be securely

tightened. Failure to do so may result in potential

fire hazard.
FOR POWER CORD INSTALLATION
A.
Remove the 3 lower screws from the terminal

block. Do not loosen the upper screws.
B. Do not cut or remove the ground strap.
C. Insert the 3 screws through each power cord

terminal ring and back into the terminal block.

Be certain the white wire is in the center.

Securely tighten each screw (35 to 50 in-lbs.)

FOR CONDUIT INSTALLATION
A.
Loosen the 3 lower screws on the terminal

block. Do not loosen the upper screws.

B. Do not cut or remove the ground strap.
C. Insert the bare wire tip (insulation stripped

5/8”) into the bottom terminal block openings.

Be certain the white wire is in the center. On

certain models, the wire must be inserted

through an opening in the ground strap.

Securely tighten each screw onto each wire

(35 to 50 in-lbs.).

NOTE: Aluminum building wire may be used but

it must be rated for the correct amperage and

voltage.

PROCEED TO STEP 5

4

4-WIRE INSTALLATION (SEPARATE GROUND WIRE)

WARNING:

Shock Hazard

The neutral wire and ground strap must be

connected as shown below for the range to

be properly grounded. Do not remove the

ground strap. Failure follow this instruction

may result in potential shock hazard.

WARNING:

Fire hazard

Terminal block screws must be securely

tightened. Failure to do so may result in

potential fire hazard.
FOR POWER CORD INSTALLATION
A.
Remove the 3 lower screws from the

terminal block. Do not loosen the upper

screws.

B. Remove the ground screw and ground plate

and retain them.

C. Cut the ground strap below the terminal

block and discard the lower section.

D. Insert the ground screw through the ground

plate (removed earlier) and back into the

range frame. Tighten securely, but do not

over-tighten (15 to 20 in-lbs.)

E. Insert the 3 terminal screws through each

power cord terminal ring and back into the

terminal block. Be certain the white wire is

in the center. Securely tighten each screw

(35 to 50 in-lbs.

FOR CONDUIT INSTALLATION
A.
Remove the 3 lower screws from the terminal

block. Do not loosen the upper screws.

B. Remove the ground screw and ground plate

and retain them.

C. Cut the ground strap below the terminal block

and discard the lower section.

D. Insert the bare ground bare wire tip (insulation

stripped 5/8”) between the range frame and

the ground plate (removed earlier) and secure

it in place with the ground screw. Tighten

securely, but do not over-tighten (15 to 20

in-lbs).

E. Insert the wire tips (insulation stripped 5/8”)

into the bottom terminal block openings. Be

certain the white wire is in the center. On

certain models, the wire must be inserted

through an opening in the ground strap.

Securely tighten each screw onto each wire

(35 to 50 in-lbs.)

NOTE: Aluminum building wire may be used but

it must be rated for the correct amperage and

voltage.

Ground

strap

Terminal block

(appearance

may vary)

Neutral

terminal

Power cord

Ground

plate

Power Cord

Wire

tips

Terminal

block

Conduit

Conduit

Red or

Black

Red or

Black

Red or

Black

Red or

Black

White

White

Terminal

block

Red or

Black

Red or

Black

Neutral

terminal

Ground plate

(grounding to

range)

Ground

screw

After–Power Cord

Green

or Bare

White

Before–Power Cord and Conduit

Terminal

block

Neutral

terminal

Ground

strap

Ground strap

or

After–Conduit

Terminal

block

Ground plate

(grounding to

range)

Wire

tips

Ground

screw

Red or

Black

Red or

Black

White

Green

or Bare

5

REPLACE THE WIRE COVER

Replace wire cover on range back by sliding

its left edge under the retaining tabs and

replace the screws removed earlier. Make

sure that no wires are pinched between

cover and range back.

Rating plate

SINGLE OVEN

7

SURFACE BURNERS

WARNING

Fire or Explosion Hazard:

Do not operate the burner without all burner
parts in place.

A. Burners - Place surface burners into

corresponding positions on cooktop.

B. Caps - Place caps on proper size burner..
C. Continuous Grates - Place the left and

right grates on the cooktop. These grates

are marked “LEFT” and “RIGHT” on their

undersides. Place the center grate with its

short edge toward the front of the range.

Left

Right

Center

or

Front right burner

Make sure the notch in the

burner head is positioned

over the electrode.

Electrode

Electrode

Hole

Notch

Cap

Burner

Cap

Power cord

Strain relief

Terminal

block

Bracket

Squeeze

connector

Terminal

block

Conduit

Bracket

Back of range

Back of range

10

LEVEL THE RANGE

WARNING

Never completely remove the

leveling leg as the range will not be secured to
the anti-tip device properly.
A.
Plug in the unit.
B. Measure the height of your countertop at the

rear of the opening (X).

C. Adjust two rear leveling legs so that the rear of

cooktop is at the same height as the counter (Y).

D. Slide unit into place.
E. Install oven shelves in the oven and position the

range where it will be installed.

F. Check for levelness by placing a spirit level on

RQHRIWKHRYHQVKHOYHV7DNHWZRUHDGLQJV³ZLWK

the level placed diagonally first in one direction

and then the other.

G. Adjust front leveling legs until the range is level.
H. Look under the unit and verify that the rear leg

is fully engaged with the anti-tip device. If not,

remove the unit and adjust the height of the

rear leg so that it is properly engaged.

Spirit level

X

Y

31-10889-2 10-13 GE

Advertising
This manual is related to the following products: