Safety Information

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT

Save these instructions for

local inspector’s use.

IMPORTANT

³

Observe all governing

codes and ordinances.

Note to Installer

³

Be sure to leave these

instructions with the Consumer.

Note to Consumer

Keep these instructions

with your Owner’s Manual for future reference.

Completion Time

³

1 to 3 hours.

• Proper installation is the responsibility of

the installer. Product failure due to improper

installation is not covered under the warranty. See

Owner’s Manual for warranty information.

WARNING

This appliance must be properly grounded. Follow

directions in ”Electric Supply” of this manual. Failure to do so

may result in electric shock.
For Monogram local service in your area,

1.800.444.1845.
For Monogram Service in Canada, call

1.800.561.3344.
For Monogram Parts and Accessories, call

1.800.626.2002.
If you received a damaged rangetop, you should

contact your dealer.
In the Commonwealth of Massachusetts:

• This product must be installed by a licensed

plumber or gas fitter.

• When using ball type gas shut off valves, they

shall be T-handle type.

• A flexible gas connector, when used, must not

exceed 3 feet.

Vent hood Combinations:

It is recommended that these rangetops be installed

in conjunction with a suitable overhead vent hood.
• Install a hood with at least 1200 CFM above a 48

wide rangetop

.

• Install a hood with at least 600 CFM above a 36”

rangetop.

Due to the high heat capacity of this unit, particular

attention should be paid to the hood and ductwork

installation to assure it meets local building codes.

WARNING:

Do not install this product with an air curtain hood or

other range hood that operates by blowing air down on

the cooktop. This airflow may interfere with operation of

the gas burners resulting in fire or explosion hazard.
Clearances to horizontal surfaces above the range,

measured to the cooking surface are below. Failure to

comply may result in fire hazard.
• Installations without a hood require 48” minimum

to combustibles.

• A custom hood installation with exposed

horizontal combustibles surfaces must have an

Auto-On feature.

• For other installations with a hood, refer to

hood installation instructions for specific hood

clearances.

CAUTION:

These rangetops are extremely heavy. Due to the

weight and size of the rangetop and to reduce the

risk of personal injury or damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER

INSTALLATION.

Installation must conform with local codes. In the

absence of local codes, the rangetop must comply

with the National Fuel Gas Code, ANSIZ223.1/

NFPA 54, latest edition and National Electrical

Code ANSI/NFPA 70 latest addition. In Canada,

installation must conform with the current Natural

Gas Installation Code, CAN/CGA-B149.1 or the current

Propane Installation Code, CAN/CGA-B149.2, and

with local codes where applicable. This rangetop has

been design-certified by CSA International according

to ANSI Z21.1, latest edition and Canadian Gas

Association according to CAN/CGA-1.1 latest edition.

Leak testing of the appliance shall be conducted

according to the manufacturer’s instructions.

If sold outside the U.S. and Canada:

WARNING:

If you wish to use this

product with Liquefied Petroleum (LP) gas

containing greater than 10% butane, you must

purchase the butane conversion kit

#WB28K10589. To order, please call

1.888.664.8403 or 1.787.276.4051. Failure to do so

may result in carbon monoxide or fire hazard.