Additional clearances

Installations without a hood require 48" minimum to
combustibles. A custom hood installation with exposed
horizontal combustible surfaces must have an “auto-on”
feature. See hood installation instructions for specific
hood clearances.

The surface of the entire back wall above the range and
below the hood must be covered with a non-combustible
material such as metal, ceramic tile, brick or stone.

10-1/2”

1-1/2”

12”

28-1/4” to

Beveled

Edge of Control

Panel Bullnose

27-1/2” to

Beveled Edge

- Maximum

Adjacent

Cabinet Depth

for

Flush

Installation

13/16”

30-36”

3-3/16”

Control Panel

Depth

28-1/4”

to Front of

Door

48-1/4”

with Oven Door

Open

31-1/16”

to Front of

Handle

35-1/4”

to

36-3/4”

7” Control

Panel Height

28-7/8”

to Front

Edge

Optional

Backsplash

Accessories

Backsplash accessories

The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.

Order ZX12B48PSS, 12" backsplash Order
ZXADJB48PSS, 30"–36" adjustable-height backsplash
with warming shelf

Side view with a backsplash