Advance planning for 30" all-gas Professional ranges

All Professional ranges are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.

Conversion kits are included with the range if the wrong gas
type was ordered. WB28K10553 high-altitude kit for operation
above 6,000 feet is also available. The kits must be installed by
a qualified service technician at additional cost.

Electrical requirements

Ranges must be connected to a 120V, 60Hz properly grounded
dedicated circuit protected by a 15-amp circuit breaker or
time-delay fuse.

Gas supply

• The natural gas models are designed to operate at 5" water

column pressure. For proper operation, the pressure of the
natural gas supplied to the regulator must be between 7"
and 13" water column.

• The LP models are designed to operate at 10" water column

pressure. For proper operation, the pressure of the LP gas
supplied to the regulator must be between 11" and 13"
water column.

Locate gas
and electrical
as shown.

Product dimensions and clearances

The serial and model numbers are located behind the far left
knob for convenience. The full rating label is located on the
bottom of the control panel—visible when the oven door is open.

Backsplash accessories

The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.

Order ZX12B30PSS, 12" backsplash
Order ZXADJB30PSS, 30"-36" adjustable-height backsplash
with warming shelf

Side view with a backsplash

10-1/2”

1-1/2”

12”

28-1/4” to

Beveled

Edge of Control

Panel Bullnose

27-1/2” to

Beveled Edge

- Maximum

Adjacent

Cabinet Depth

for

Flush

Installation

13/16”

30-36”

3-3/16”

Control Panel

Depth

28-1/4”

to Front of

Door

48-1/4”

with Oven Door

Open

31-1/16”

to Front of

Handle

35-1/4”

to

36-3/4”

7” Control

Panel Height

28-7/8”

to Front

Edge

Optional

Backsplash

Accessories

Additional clearances

Installations without a hood require 48" minimum to combustibles.
A custom hood installation with exposed horizontal combustible
surfaces must have an “auto-on” feature. See hood installation
instructions for specific hood clearances.

The surface of the entire back wall above the range and below
the hood must be covered with a non-combustible material such
as metal, ceramic tile, brick or stone.