Design guide, The installation space, Grounding the refrigerator – GE ZIC30GNDII User Manual

Page 5

Advertising
background image

Water and Electrical Locations

Electrical and water supply should be located in shaded area only as shown.

PREPARING INSTALL WATER LINE
• A cold water supply is required

for automatic icemaker operation. The water pressure must be
between 40 and 120 p.s.i.

• Route 1/4" OD copper or GE SmartConnect

plastic tubing between

the house cold water line and the water connection location.

• Tubing should be long enough to extend to the front of the

encloasure.

• Water line can enter an opening through the floor or back wall.
• Install a shut-off valve between the icemaker water valve and cold

water supply in the home.

NOTE:
• It is recommended that the water shut-off valve be placed in a

location that is easily accessible. We do not advise placing it behind
the unit because of access difficulties. If it is necessary to install the
valve behind the unit, it must be located in the shaded area.

• Saddle type shut-off valves are included in many water supply kits, but are

not recommended for this application.

• The only GE-approved plastic tubing is supplied in the GE

SmartConnect

Refrigerator Tubing kits. Do not use any other plastic water supply line because the line is under

pressure at all times. Other types of plastic may crack or rupture with age and cause water damage to your home. GE
SmartConnect

Refrigerator Tubing Kits are available in the following lengths:

6' (1.8 m) WX08X10006, 15' (4.6 m) WX08X10015 & 25' (7.6 m) WX08X10025

• Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not

permitted in Massachusetts. Consult with your licensed plumber.

Electrical Specifications

• A 115-volt, 60-Hz., 15- or 20-amp power supply is required. An individual properly grounded branch circuit or circuit

breaker is recommended.

• Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear

wall as shown.

NOTE: GFI (ground fault interrupter) is not recommended.

6”

80”

77”

Anti-Tip location. Do
not obstruct this area.

Water and Electrical
Tube Outlet

Front view

Install Space

THE INSTALLATION SPACE

Design Guide

5

Where a standard 2-prong wall outlet is encountered, it
is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.

DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG FROM
THE POWER CORD.

DO NOT USE AN ADAPTER PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG OUTLET.

DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE.

GROUNDING THE REFRIGERATOR

IMPORTANT—(Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.

The power cord of this appliance is equipped with
a 3-prong (grounding) plug which mates with a
standard three-prong (grounding) wall receptacle
to minimize the possibility of electric shock hazard
from this appliance.

Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.