* No relay clicking in control box. Table then functions after about 30 minutes.

Front cabinet switches; 1 or more

of 6 is not closing when pressed.

Press each one and listen for click

when pressed and again when

released. Replace as necessary.

Start Here

Complete the operational test

Test fails

Test passes

Test Complete

No movement

Some

movement

Go to step 2.1

Go to step 2.2

Does the drawer warmer heat

properly? Does outlet work?

Yes or N/A

No

Call 1 888-Brewer1 for technical

assistance.

Call 1 888-Brewer1 for technical

assistance.

Fixed

Still bad

Seat back switches; 1 or more of 4

is not opening when pressed.

Press each one and listen for click

when pressed and again when

released. Replace as necessary.
Fixed

Yes

No

Return to step 1

Control box is over temperature.

Allow 30 minute cool down.

Control box resets automatically.

Yes

No

No

Yes

Is there excessive noise or other

problems which are not yet

identified?

Go to step 5.1 for Heater

Go to step 6.1 for Outlet

Go to step 7.1

Table stops after period of heavy

use. *see below

Still bad

Do all powered functions work?

Yes

No

Do the 6 front limit switches

work properly?

Yes

No

Do the 4 seat back limit switches

work properly?

6000 SERIES TABLE TROUBLESHOOTING CHART