WARNING

When performing a cauterization or similar treat-

ment, the patient must be insulated from the metal

portions of the table by non-conductive material.

Failure to do so may result in electrical shock or

burns to the patient.

WARNING

Use 115 VAC, 60 Hz as noted on the rating label.

Failure to do so may result in electrical shock to

personnel and will result in damage to the table.

WARNING

Do not use this table in an explosive or oxygen-

enriched atmosphere. Failure to do so may result

in serious personal injury or death.

CAUTION

Do not use any power supply other than that

listed on the rating label (Figure 1). Failure to do

so may result in serious injury and/or equipment

damage.

SPECIFICATIONS

Fuse Rating:
Control Box Fuse Rating, 120V Models ............ 250V/2.5A
Option/Warmer Fuse Rating .............................. 250V/1.0A
Option/Warmer & Outlet Fuse Rating ................ 250V/3.0A
Duty Cycle (10%)

.................... 2 minutes on / 18 minutes off (motor run time)
Power Cord............... Extends 70 in. (Minimum) from table.

120V Models: 18 AWG / 3 conductor, SJT grey jacketed

junior hard service with hospital plug or detachable

power cord.
Type of protection
against electrical shock
Model 6000, 6500 and 6800 ........ Class 2 Double Insulated
Models 6001, 6501 and 6801 ................. Class 1 Grounded
Type of protection

against electrical shock ............................... B applied parts
Type of protection against ingress of water……. Ordinary

Can accept paper rolls of

18 in. x 3.0 in.

.................................................................. or 21 in. x 3.0 in.
Certifications* ..............................UL60601-1; IEC60601-1;

..................................................CAN-CSA C22.2 No. 601.1
Operating Conditions:

Temperature Range ...........................................65° to 85°F
Relative Humidity..............................................10% to 90%
Transportation and Storage
Temperature .................................................-20°F to 150°F
Humidity............................................................10% to 90%
* UL classified in the United States and Canada

per the standards listed above.

Weight of Table (

Models 6000, 6001, 6500 & 6501

) .. 395 lbs.

Weight of Table (

Model 6800

) ..................................

423 lbs

Weight of Table (

Model 6801

) ..................................

432 lbs

Load Rating (maximum):
- Seat/Back 6800/6801 .......................................... 700 lbs.
- Seat/Back 6000/6001/6500/6501 ........................ 450 lbs.
- Leg Support .......................................................... 50 lbs.
- Leg Extension ....................................................... 50 lbs.
- Pass Through Work Surface ................................. 15 lbs.
- Grab Bars ............................................................ 100 lbs.
Back Section Range .................0° (horizontal) to +80° ± 5°
Table Top Height Range .............18 ± 0.5 in. to 37 ± 1.0 in.
Pelvic Tilt Range
(Models 6001/6501/6801 Only) ....0° (horizontal) to 5° (up)
Upholstery Dimensions:

Upholstered Top ........................ 28.0 in. wide x 60 in. long
Upholstered Leg Support……15.25 in. long x 18.5 in. wide
Upholstered Leg Extension…....6.0 in. long x 15.5 in. wide

Overall Length ................................................... 60 in. long
With Leg Support Extended............................... 72 in. long
With Leg Extension Extended ........................... 78 in. long
Electrical Requirement

6000/6500/6800

........

115 VAC nominal, 60 HZ, 5.8 amps max.

6001

.........................

115 VAC nominal, 60 HZ, 6.3 amps max.

6001/6501/6801 W/Outlet

...

115 VAC nominal, 60 HZ, 9.3 amps

max.

ELECTRICAL REQUIREMENTS

CAUTION

This product has been evaluated with respect to

electrical shock, fire, and mechanical hazards only

in accordance with UL60601-1; IEC60601-1;

CAN/CSA C22.2 No. 601.1

Electromagnetic Interference

This product is designed and built to minimize electromag-

netic interference with other devices; however, if interfer-

ence is noticed between another device and this product,

remove the interfering device from the room or plug this

product into an isolated circuit.

Advertising