E L E c T R I c A L c O N N E c T I O N

I N S T A L L A T I O N

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “OFF” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

REGARDiNG iNTERNATiONAL STANDARD UNiTS:

If the unit is not equipped with flexible cord and

plug, an all-pole country approved disconnection

device which has a contact separation of at least

3mm in all poles must be incorporated in the fixed

wiring for disconnection. When using a cord

without a plug, the green/yellow conductor shall

be connected to the terminal which is marked with

the ground symbol. If a plug is used, the socket

outlet must be easily accessible. If the power cord

needs replacement, use a similar one obtained

from the distributor.

d A N g E R

ENSURE POWER SOURCE
MATCHES VOLTAGE iDENTiFiED
ON APPLiANCE RATiNG TAG.

d A N g E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSi/
NFPA No. 70. in Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

NOTE

:

CE approved appliances must be

connected to an electrical circuit that is

protected by an external GFCI outlet.

hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

d A N g E R

APPLiANCES WiTH NO CORD
PROViDED BY FACTORY MUST
BE EQUiPPED WiTH A CORD OF
SUFFiCiENT LENGTH TO PERMiT
THE APPLiANCE TO BE MOVED
FOR CLEANiNG.
ELECTRiCAL CONNECTiONS MUST
BE MADE BY A QUALiFiED SERViCE
TECHNiCiAN iN ACCORDANCE WiTH
APPLiCABLE ELECTRiCAL CODES.

for CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.