1

PARTS IDENTIFICATION

DOWN PRESSURE REGULATING VALVE KIT

The down-pressure regulating valve kit replaces the two “T” fittings, in the middle of the cart, joining
together hoses from the toolbar cylinders.

CAUTION:

DO NOT ride on machine to adjust down-pressure or you could

fall off and be run over resulting in severe injury or death.

NOTE: This down-pressure regulating valve kit is for use with tractors with closed center hydraulics only.

NOTE: MUST have gauge wheels on toolbar.

NOTE: This hydraulic system does not compensate for conditions varying from soft to hard as you travel
through the field.

When adjusting active hydraulic down-pressure it is important to remember the following:

-

Seed depth is largely controlled by coulter depth when using a coulter cart.

-

The active hydraulic down-pressure system keeps the toolbar gauge wheels in contact with the soil
surface as the ground contour changes.

-

The amount of down-pressure required depends upon soil hardness, moisture and residue cover.

-

The recommended initial setting is between 400 and 600 psi.

IMPORTANT: Excessive down-pressure can increase wear, increase draft loads, decrease effective seed
depth and reduce gauge wheel bearing life. Use only as much pressure as necessary to achieve
consistent operating depth.