FR1052

Positive disconnection 12V

INSULATED SOLENOID (power supply coil from battery)

Passive Disconnect (Ignition OFF Battery Disconnection)

This installation uses a momentary switch (Not Included) to energize
the vehicles electrical system, then uses the ignition system to main-
tain the disconnect switch in the closed (on) position. When the igni-
tion is turned off, the disconnect switch automatically opens (off) and
the electrical system is disconnected.

1. Positive battery cable is connected to terminal 30-31
2. Vehicle load is connected to terminal 30A-31A
3. Terminal 85 (NEG.BOB.) is connected to chassis ground.
4. Terminal 86 (POS.BOB.) is connected to one side of momentary

switch and is connected to an “ignition on” circuit (i.e. Switch “IGN/
RUN” terminal)

5. Other side of momentary switch is connected to constant positive.

(Any style of momentary switch is acceptable, 10 amp or greater).

• Always use proper wiring techniques.
• Wire size should be determined using industry standards based

upon load requirements and length of cable needed.

• Activation solenoid has a max draw of 4.4 amps, 0.4 amps continu-

ous.

• Main terminals are rated for 250 amps continuous, 2500 amps

peak.

• We always recommend the use of Battery Terminal Covers

FR1003TM.