Installing the New Water Heater (cont’d)

4. Ease the roof jack assembly through the roof and ceil-

ing openings. The roof jack flashing tilts up to 22.6°

degrees for use on a sloping roof.

FLUE PIPE

TELESCOPE

OUTER PIPE

AND

FLUE PIPE

DOWN

OUTER PIPE

1. Cut 5

1

2

″ diameter holes through the roof and ceiling

directly in line with the flue connection on top of the

water heater. For a sloped roof, the roof hole may have

to be enlarged to allow the roof jack to be installed

vertically.

2. Telescope down the flue pipe in the roof jack assembly

to a length that will project at least 6

″ below the fin-

ished ceiling before installing the roof jack assembly.

NOTE: Flue pipe joints have silicone seals that must

remain in place. A soapy water solution sprayed around

the seal area will enable the flue pipe and outer pipe

below to telescope more freely.

3. Telescope down the outer pipe of the roof jack assem-

bly to a length that will project at least 2

″ below the

finished ceiling before installing the roof jack assem-

bly.

Roof Jack Installation

Roof Jack Kit Models VENT KIT / 12 IN. (9002964), VENT KIT / 32 IN. (9002965),
VENT KIT / 60 IN. (9002966), and VENT KIT / 95 IN. (9002967)

VENT KIT / 95 IN.

VENT KIT / 60 IN.

Adj. 0-22.6°
MAX. PITCH 5-12

VENT KIT / 32 IN.

VENT KIT / 12 IN.

96

″″ MAX.

49

″″ MIN.

136

MAX.

55

MIN.

100

MAX.

40

MIN.

72

MAX.

25

MIN.

32

MAX.

17

MIN.

52

MAX.

18

MIN.

12

MAX.

2

MIN.

23

MAX.

56

22.6

60

MAX.

32

MIN.