Installing the new water heater (cont’d), Water piping, Water piping pressure test – State PR6 40 NHDST2 User Manual

Page 15: Warning

Advertising
background image

If a water heater is installed in a closed water supply sys-

tem; such as one having a back-flow preventer, check

valve, water meter with a check valve, etc... in the cold

water supply; means shall be provided to control thermal

expansion. Contact the water supplier or plumbing con-

tractor on how to control this situation.

NOTE: To protect against untimely corrosion of hot and

cold water fittings, it is strongly recommended that di-

electric unions or couplings be installed on this water

heater when connected to copper pipe.

NOTE: This water heater is super insulated to minimize

heat loss from the tank. Further reduction in heat loss

can be accomplished by insulating the hot water lines

from the water heater.

The illustration shows the attachment of the water piping

to the water heater. The water heater is equipped with

3

4

water connections.

NOTE: If using copper tubing, solder tubing to an

adapter before attaching the adapter to the cold water

inlet connection. Do not solder the cold water supply

line directly to the cold water inlet. It will harm the dip

tube and damage the tank.

Installing the New Water Heater (cont’d)

Water Piping

SHUTOFF

VALVE

COLD INLET

WATER LINE

DISCHARGE PIPE

(Do not cap or plug.

Must terminate beneath

manufactured home,

unless drain pan is

installed.)

HOT OUTLET

TO HOUSE

3/4

″″ THREADED

COUPLINGS

TEMPERATURE-

PRESSURE RELIEF

VALVE

ELBOW

WATER PIPING PRESSURE TEST

This section is only for the manufacturer installing the

water heater when the installation is to comply with

H.U.D. Standards.
When testing the water ways, H.U.D. Standards state:

“Water distribution system. All water piping in the

water distribution system shall be subjected to a pres-

sure test. The test shall be made by subjecting the sys-

tem to air or water at 100 psi for 15 minutes without

loss of pressure. When air pressure is used, the water

heater shall not be connected during the test.

WHEN AIR TESTING,

REMOVE THE WATER

LINES FROM THE

WATER HEATER

HOT OUTLET

COLD INLET

15

GAS SUPPLY

SHUTOFF

VALVE

TEE

DRIP LEG

(SEDIMENT TRAP)

PIPE CAP

DRAIN VALVE

WARNING

HOTTER WATER CAN SCALD: Water heaters are

intended to produce hot water. Water heated to a tem-

perature which will satisfy clothes washing, dish wash-

ing, and other sanitizing needs can scald and perma-

nently injure you upon contact. Some people are more

likely to be permanently injured by hot water than oth-

ers. These include the elderly, children, the infirm, or

physically/mentally handicapped. If anyone using hot

water in your home fits into one of these groups or if

there is a local code or state law requiring a certain

temperature water at the hot water tap, then you must

take special precautions. In addition to using the lowest

possible temperature setting that satisfies your hot

water needs a means, such as a mixing valve, should be

used at the hot water taps used by these people or at

the water heater. Mixing valves are available at plumb-

ing supply or hardware stores. Follow manufacturer’s

instructions for installation of the valves. Before chang-

ing the factory setting on the thermostat, read the

“Temperature Regulation” section.

WARNING

This water heater shall not be connected to any heating

systems or component(s) previously used with a non-

potable water heating appliance.

WARNING

Toxic chemicals such as used for treatment of boilers or

non-potable water heating appliances shall never be

introduced into a potable water space heating system.

WARNING

If the water piping system is to be air pressure tested,

the water heater must be disconnected from the water

piping system. Failure to disconnect the water heater

during air pressure testing of the water piping system

could result IN DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.