Installing the new water heater (cont’d), Installation checklist, Warning – State PR6 40 NHDST2 User Manual

Page 18

Advertising
background image

Installation Checklist

BEFORE LIGHTING THE PILOT:

VENT CAP

PIPE CAP

HOT

COLD

DRIP LEG

(Sediment trap)

GAS SUPPLY

SHUTOFF VALVE

TEMPERATURE-PRESSURE

RELIEF VALVE

UNION

TEE

DISCHARGE PIPE

(Do not cap or plug.

Must terminate

beneath manufactured

home, unless drain pan

is installed.)

ROOF JACK

Installing the New Water Heater (cont’d)

18

SHUTOFF VALVE

MODEL RATING PLATE

* For 30 Gal. heater: as shown above

For 40 Gal. heater:

ORIFICE SIZE: #38 FOR NAT. / #51 FOR LP
IF CONVERTED - PROPANE RATE: 32,000 BTU

For 50 Gal. heater:

ORIFICE SIZE: #35 FOR NAT. / #51 FOR LP
IF CONVERTED - PROPANE RATE: 38,000 BTU

*

SUITABLE FOR WATER (POTABLE)
HEATING ONLY

AUTOMATIC STORAGE WATER HEATER FOR
DIRECT VENT INSTALLATION IN A MFG. HOME

ORIFICE SIZE: #40 FOR NAT. / #52 FOR LP
IF CONVERTED - PROPANE RATE: 30,000 BTU

WARNING

Contaminants in the gas lines may cause improper opera-

tion of the gas control valve that may result in fire or explo-

sion. Before attaching the gas line be sure that all gas pipe is

clean on the inside. To trap any dirt or foreign material in

the gas supply line, a drip leg (sometimes called a sediment

trap) must be incorporated in the piping. The drip leg must

be readily accessible. Install in accordance with the “Gas

Piping” section. Refer to the latest edition of the National

Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54.

1. Check the gas line for leaks.

a. Use a soapy water solution. DO NOT test for gas

leaks using a match or open flame.

b. Brush the soapy water solution on all gas pipes,

joints and fittings.

c. Check for bubbling soap. This means you have a

leak. Turn “OFF” gas and make the necessary

repairs.

d. Recheck for leaks.

e. Rinse off soapy solution and wipe dry.

2. Is the new temperature-pressure relief valve properly

installed and piped to an adequate drain? See

“Temperature-Pressure Relief Valve” section.

3. Are the cold and hot water lines connected to the

water heater correctly? See “Water Piping” instruc-

tions in the “Installing the New Water Heater” sec-

tion.

4. Is the water heater completely filled with water? See

“Filling the Water Heater” instructions in the

“Installing the New Water Heater” section.

5. Will a water leak damage anything? See the “Locating

the New Water Heater” section.

6. Is there proper clearance between the water heater

and anything that might catch fire? See the “Locating

the New Water Heater” section.

7. Do you have adequate ventilation so that the water

heater will operate properly? See the “Locating the

New Water Heater” section.

8. Is the vent piping properly secured? See “Installing the

New Water Heater” section.

9. Is there proper clearance between the vent pipe and

anything that might catch fire? See “Installing the New

Water Heater” section.

10. Is the vent pipe properly sloped and does the vent ter-

minate outdoors? See “Installing the New Water

Heater” section.

11. Do you need to call your gas company to check the

gas pipe and its hookup?