Installing the New Water Heater (cont’d)

Step 20. At arm’s length away, set the thermostat to desired

setting. The mark (

▼) HOT indicative of approx.

120°F is preferred starting point. If hotter water is

desired see the “Temperature Regulation” section

in this manual.

Step 21. Replace the outer door if not replaced in step 17.

Step 22. Remove adhesive label found in conversion kit

and place next to the model rating plate. Mark

label indicating for which type gas the water

heater is now equipped.

“Fuel” Conversion Instructions

From Propane (L.P.) Gas To

Natural Gas

To convert from Propane (L.P.) gas to Natural gas, follow

the “Fuel” Conversion Instructions From Natural Gas to

Propane (L.P.) Gas” section except in Step 5, use orifice

“E”, marked “NAT.”. In Step 6 use pilot orifice “G”, silver

color and in Step 8 turn control screw “B” in Figure 6

clockwise ( ) to stop. Screw must be in “OUT” posi-

tion for Natural gas.

See “Instruction Label” for orifice sizes.
Maximum Supply Pressure:

10.5

″ W.C. For Nat. Gas.

13

″ W.C. for Propane (L.P.) Gas

Minimum Supply Pressure

5

″ W.C. for Nat. Gas.

11

″ W.C. For Propane (L.P.) Gas

“B”

“A” GAS CONTROL

KNOB

TEMPERATURE

ADJ. DIAL

OUT FOR NATURAL

IN FOR PROPANE (L.P.)

Figure 9

PLASTIC CAP

MANIFOLD

PILOT TUBING

THERMOCOUPLE

NUT “K”

NUT “J”

NUT “H”

Figure 10a

BRACKET

MANIFOLD

BURNER

“D”

“E”

Figure 11

“G”

“F”

Figure 12

INLET

GAS

LINE

Figure 10b

PILOT DOOR

INNER DOOR

WARNING

Hotter water increases the risk of scald injury. Before

changing temperature setting see the “Temperature

Regulation” section in this manual.

WARNING

This water heater has been factory equipped to operate with

the type gas indicated in the “EQUIPPED FOR” area of the

model rating plate located near the gas control valve. The

indicated gas may be either Natural or Propane (L.P.). By fol-

lowing the conversion instructions in this manual or the

instructions near the gas control valve, the water heater must

be converted if it is to be used with the opposite gas. DO

NOT USE THIS WATER HEATER WITH ANY GAS OTHER

THAN THE ONE LISTED ON THE MODEL RATING PLATE.

Failure to use the correct gas can cause problems which can

result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE. If you have any questions or doubts consult your

gas supplier or gas company.