TWO TEMPERATURE - TWO HEATERS HIGH TEMPERATURE STORAGE

WITH OR WITHOUT RECIRCULATION

* PIPE RELIEF VALVE TO OPEN DRAIN

NOTE: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE

SHOULD BE CONNECTED AT POINT "A"

FOR MULTIPLE HEATER INSTALLATION SEE MANIFOLD KIT

SPECIFICATIONS, PAGES 19.

DANGER:

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE

TEMPERATURES AT FIXTURES. SEE WATER TEMPERATURE

CONTROL WARNING ON PAGE 10. IF HIGHER PREHEAT

TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE

BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT

WATER SUPPLIED TO FIXTURES.

WIRING DIAGRAM FOR 180°F (82.2°C) LOOP (IF USED)

INSTALL IN ACCORDANCE WITH LOCAL CODES

WIRING DIAGRAM FOR TEMPERED WATER LOOP

(IF USED)

INSET A

INSTALL THERMAL EXPANSION

TANK IN COLD WATER SUPPLY LINE,

IF CHECK VALVE OR PRESSURE

REDUCING VALVE IS USED IN

SUPPLY.

INSET B

VACUUM RELIEF VALVE

INSTALL PER LOCAL CODES.