State GPO 69 700OE User Manual

Page 18

Advertising
background image

18

TWO TEMPERATURE-ONE HEATER HIGH TEMPERATURE STORAGE

WITH RECIRCULATION OF SANITIZING LOOP

NOTE 1: TOGGLE SWITCH CONTROLS 180°F WATER CIRCULATION.

INSTALL ON OR CLOSE TO DISHWASHING MACHINE .

TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE

RINSE OPERATION AND OPEN (OFF) WHEN DISHWASHER

IS NOT OPERATING.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL IN AN

UNINSULATED TEE BEYOND THE DISHWASHING MACHINE

TAKEOFF IN THE SANITIZING LOOP. CONTROL SHOULD BE

SET AT 185°F (85°C).

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW

RATE DOES NOT CAUSE UNNECESSARY TURBULENCE

IN THE TANK.

NOTE 4: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE

SHOULD BE CONNECTED AT POINT "A".

WIRING DIAGRAM FOR 180° LOOP (IF USED)

INSET A

INSTALL THERMAL EXPANSION

TANK IN COLD WATER SUPPLY

LINE, IF CHECK VALVE OR

PRESSURE REDUCING VALVE

IS USED IN SUPPLY.

INSET B

VACUUM RELIEF VALVE

INSTALL PER LOCAL CODES.

NOTES