1. Turn off all electric power to the water heater if service is to be performed. 
2. Turn the manual gas valve located on the outside of the unit clockwise  to the 

off position. 

Do  not  use  this  water  heater  if  any  part  has  been  submersed  under  water. 
Immediately call a licensed professional to inspect the water heater to replace 
any damaged parts. 

Do not reverse the hot outlet and cold inlet connections to the water heater.  
This will not properly activate the water heater. 

 

‐Measuring inlet gas pressure‐ 

 
 
 

 

 
 
 

The water heater cannot perform properly without sufficient inlet gas pressure. Below are instructions 
on how to check the inlet gas pressure. THIS IS ONLY TO BE DONE BY A LICENSED PROFESSIONAL.  
 
1. Shut off the manual gas valve on the supply gas line. 
2. Remove the screw for the pressure port located on 

the gas inlet of the water heater shown in the 
diagram to the right. 

3. Connect the manometer to the pressure port. 
4. Re‐open the manual gas valve. Check to see that 

there are no gas leaks.  Open some of the fixtures 
that use the highest flow rate to turn on the water 
heater. 

5. Check the inlet gas pressure. When the water heater 

is on maximum burn, the manometer should read 
from 5.0” to 10.5” WC for Natural gas, from 8.0” to 
14.0” WC for Propane. 

 

WATER CONNECTIONS 







All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for 
potable water systems.   

1.

A manual shut off valve must be installed on the 
cold water inlet to the water heater between the 
main water supply line and the water heater.  

2.

In  addition,  a  manual  shut  off  valve  is  also 
recommended on the hot water outlet of the unit. 
If  the  water  heater  is  installed  within,  or 
subjected  to,  a  closed  loop  water  system,  a 
thermal expansion tank must be installed.  

3.

Before  installing  the  water  heater,  flush  the 
water  line  to  remove  all  debris,  and  after 
installation  is  complete,  purge  the  air  from  the 
line.  Failure to do so may cause damage to the 
heater.  

4.

There is a wire mesh filter within the cold inlet to trap debris from entering your heater. This will 
need to be cleaned periodically to maintain optimum flow.  