38

Page

 

Only pipes within the water heater are protected by the freeze protection 
system.  Any water pipes (hot or cold) located outside the unit will not be 
protected.  Properly protect and insulate these pipes from freezing. 

Household Flow Rates

Taken from UPC 2006 

 

FLOW 

 The flow rate through the water heater is limited to a maximum of 9.0 GPM for the 520 (T‐H2) 

models, and 8.0 GPM for the 320 (T‐H2S) models.  

 The temperature setting, along with the supply temperature of the water will determine the flow 

rate output of the unit.   

 Please refer to the temperature vs. gallons per minute chart on p. 50 to determine the likely flow 

rates based on your local ground water temperature and your desired outlet water temperature 
combination. 

 Based on the United States Department of Energy 

method of testing water heater output, the 520 (T‐H2) 
models is rated for 282 gallons per hour (GPH) or 4.8 
gallons per minute (GPM) for Natural Gas, and the 320 
(T‐H2S) models is rated for 255 gallons per hour (GPH) or 
4.3 gallons per minute (GPM) for Natural Gas, when 
raising the water temperature by 77F (from 58F to 
135F).  

 Refer to the chart to the right for typical household 

plumbing fixture flow rates to determine what the water 
heater can do in a household application.  

 
 

FREEZE PROTECTION SYSTEM 

 This unit comes equipped with heating blocks to protect it against damages associated with freezing.  
 For this freeze protection system to operate there has to be electrical power to the unit. Damage to 

the  heat  exchanger  caused  by  freezing  temperatures  due  to  power  loss  is  not  covered  under  the 
warranty.  In cases where power losses can occur, consider the use of a backup power supply. 

 The freeze protection system will activate when the surrounding and/or outside temperatures drop 

below 36.5°F (2.5°C). 

 In  any  areas  subject  to  freezing  temperatures,  the  manufacturer  highly  recommends  an  indoor 

installation with the Direct Vent Indoor models.  In such an installation, freezing issues can only occur 
if cold air enters through the venting into the heat exchanger, whether by negative pressures within 
the installation location or by strong outside winds.  It is the installer’s responsibility to be aware of 
these issues and take all preventative measures.  The manufacturer will not be responsible for any 
damage to the heat exchanger as a result of freezing.  

 The  manufacturer  also  highly  recommends  the  use  of  a  back  flow  vent  damper  to  minimize  the 

amount of cold air entering through the exhaust venting when the water heater is off. 

 If you will not be using your heater for a long period of time: 

1. Completely drain the unit of water. Refer to p. 39.  
2. Disconnect power to your heater.      

    This will keep your unit from freezing and being damaged.

 

Appliance / Use 

Flow Rate (GPM) 

Lavatory Faucet 

1.0 

Bath Tub 

4.0 – 10.0 

Shower 

2.0 

Kitchen Silk

1.5 

Dishwasher 

1.5 

Washing machine 

4.0 