Installation 

22

Page

 

The  condensate  drain  is  at  atmospheric  pressure  (non‐pressurized)  and 
therefore  must  be  allowed  to  drain  freely  with  gravity  only.    Please  ensure 
that there are no blockages along the condensate drain tube.  All portions of 
the  condensate  drain  (neutralizer  and  drain  tube)  must  be  at  a  lower 
elevation than the water heater to prevent condensate water from building 
up inside the heat exchanger.
 

 

Condensate  cannot  be  effectively  neutralized  if  the  neutralizer  elements 
inside  the  Neutralizer  accessory  have  been  completely  consumed.    If  this 
happens,  Condensate  will  remain  acidic  and  can  possibly  cause  damage  to 
items such as pipes, concrete, etc., if drained improperly. 

 

The Neutralizer cartridge is designed to last for 3 years before replacement.  
However, the actual life of the neutralizer may vary, depending on the 
application and usage.  Please ensure that the cartridge is properly replaced 
before the neutralizer elements have been completely consumed. 

 

All preventative measures and safety practices must be adhered to when 
draining condensate.  The manufacturer will not be responsible for any 
damage caused by condensate. 

A drain pan, or other means of protection against water damage, is required 
to be installed under the water heater in case of leaks. 

Follow the electrical code requirements of the local authority having 
jurisdiction. In the absence of such requirements, follow the latest edition of 
the National Electrical Code ANSI/NFPA 70 in the U.S. or the latest edition of 
CSA C22.1 Canadian Electrical Code, Part 1, in Canada.

When servicing or replacing parts within the water heater, label all wires 
prior to disconnection to facilitate an easy and error‐free reconnection.  
Wiring errors can cause improper and dangerous operation. Verify proper 
operation after servicing. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ELECTRICAL CONNECTIONS 











1.

The water heater must be electrically grounded. Do not attach the ground wire to either the gas or 

the water piping.

 

2.

The water heater requires 120 VAC / 60 Hz electrical power supply that is properly grounded. 
 A proper disconnect (i.e. on/off switch, power plug, etc.) controlling the main power to the 

water heater must be provided for service reasons.  (Must comply with local codes). 

 Connect the power supply to the water heater exactly as shown in the wiring diagram;  

 

3.

A green screw is provided in the junction box to ground the connection.  

4.

Can be hardwired or wired to a plug‐in.  

5.

The  use  of  a  surge  protector  is 
recommended  in  order  to 
protect  the  unit  from  power 
surges.  

 

 

 

WARNING 

WARNING 

CAUTION 

Connect Power supply 

120 VAC / 60 Hz 

Ground 