Connecting Batteries

WARNING

Do not connect the batteries until AWS330 is ready for powering.

The work order for connecting the AWS330 backup batteries:

1.

Insert the flat connectors to battery terminals.

2.

Mount the batteries and hook the straps.

3.

When ready for powering, connect the battery cables to the flat
connectors.

1012-213

Figure 53

Connecting Battery

The following numbers refer to Figure 53 above:
1 = Screw M4x16 DIN933 A4; use wrench 7 mm
2 = Spring washer B4 DIN127 A4
3 = Washer A4.3 DIN125 A4
4 = Flat

terminal

5 = Battery

cable

6 = Nut M4 DIN934 A4; wrench 7 mm

Advertising