Observation Values

Depending on the selected sensor configuration, the AWS330 system
produces various statistical and derived meteorological outputs.

The following tables list outputs by category.

Values with 1 minute or shorter period are regarded as instant values, that
is, they are averaged from several samples. These values are used further
to calculate statistical values for longer periods.

Air Temperature and Relative Humidity

Table 4

Parameters for Air Temperature and Relative
Humidity

Reported Parameter

Unit

Statistic

Period

Interval Message Tag

Dry bulb temperature

°C

Average

1 min

10 s

TAAVG1M

Dry bulb temperature

°C

Average

1 hour

1 hour

TAAVG1H

Dry bulb temperature

°C

Average

1 day

1 day

TAAVG1D

Dry bulb temperature

°C

Minimum 18:00–06:00 24 hours TAMIN1D

Dry bulb temperature

°C

Maximum 06:00–18:00 24 hours TAMAX1D

Relative humidity

%

Average

1 min

10 s

RHAVG1M

Relative humidity

%

Average

1 hour

1 hour

RHAVG1H

Dewpoint

(1

°C

Average

1 min

1 min

DPAVG1M

Dewpoint

(1

°C

Average

1 hour

1 hour

DPAVG1H

Wet bulb temperature

(1

°C

Average

1 min

1 min

TBAVG1M

Wet bulb temperature

(1

°C

Average

1 hour

1 hour

TBAVG1H

Heat index

(1

°C

Average

1 min

1 min

HIAVG1M

Wind chill

(1

°C

Average

1 min

1 min

WCHAVG1M

(1

See Appendix B on page 273 for calculation formula.