User's Guide ______________________________________________________________________

30 __________________________________________________________________ M211296EN-B

Alarm Messages

Alarms are sent using plain text messages formatted in similar manner as
observation message CSV. The actual message does not contain
linefeeds; the description below is split into two lines for readability.

(S:<StationName>;D:<YYMMDD>;T:<hhmmss>;
ALARM:<Alarm reason>;<ValueTag>:<Value>)

where
<StationName>

= Name of the observation site

<YYMMDD>

= Message date UTC, for example 101126

<hhmmss>

= Message time UTC, for example 085300

<Alarm reason>

= Short description of the source

<ValueTag> =

Message

tag

for

the alarming value (optional)

<Value>

= Value of the alarming variable (optional)

;

= Separator character between fields

: =

Separator

character

between tag and value

Example alarm message:

(S:AWS330;D:101129;T:091500;ALARM:Windspeed;WSMAX10M:30.0)

Table 15

Sensor Alarms

Monitored Sensor

Message

HMP155/Temperature

Air temperature sensor failure

HMP155/Relative humidity

Humidity sensor failure

BARO-1

Barometric pressure sensor failure

WMT703/Wind direction

Wind direction sensor failure

WMT703/Wind speed

Wind speed sensor failure

WAV15/WAA15

N/A. Sensor failure is not detectable by
AWS330

RG13

N/A. Sensor failure is not detectable by
AWS330

CMP6

Solar radiation sensor failure

QMT110

Soil temperature 1/2 sensor failure

IRU9429

Snow height sensor failure

Example sensor alarm message:

(S:AWS330;D:101209;T:091600;ALARM:Humidity sensor failure)

Sensor failure alarms can be sent as above or as an attachment to table
message. For an example, see section Table Message with Alarm List on
page 291.